DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM Signal valve - Unidentified failure (A.10.A.12 - G.30.B.46) AFX8010 E0190-11 - Jammer Valve Cause: The signal valve solenoid (L-43) circuit is open, or shorted to ground. Possible failure modes: 1. Supply wiring damaged. 2. Bad solenoid. 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "GRAIN HANDLING" or "HEADER" sort menu, and select "JAMMER VLV". Change the drop-down list to "STATUS", and press the "OFF" button to change the circuit output to "ON". The "STATUS" screen should indicate "OK" if the circuit is working properly. A.
If the status screen indicates "ERROR", the circuit is open or shorted to ground. Continue with Step 2 . B. If the status screen indicates "OK", the circuit is working properly. Continue with Step 9 . 2. Disconnect connector X022 . Use a multimeter to check between connector X022 pin 1 or 8 (valve side) and chassis ground. A. If there is continuity, the signal valve solenoid is shorted to ground. Replace the solenoid. 3. Use a multimeter to check for continuity between connector X022 pin 1 (harness side) and chassis ground. Flex the main frame (MF) harness between the signal valve and connector X008 while making this check. B. If there is no continuity, continue with Step 3 . A.
If there is continuity to ground, continue with Step 4 . B. If there is no continuity to ground, continue with Step 5 . 4. Disconnect connector X008 . Use a multimeter to check for continuity between connector X008 pin 2 and chassis ground. Flex the front frame (FF) harness between the connector X008 and connector X017 while making this check. A. If there is no continuity to ground, the short to ground is in the main frame (MF) harness between connector X008 and connector X022 wire 1119 white. Locate the short and repair. B. If there is continuity to ground, the short to ground is in the front frame (FF) harness between connector X008 and connector X017 wire 1119 white.
Locate the short and repair. 5. Disconnect connector X022 . Use a multimeter to check the resistance of the signal valve coil between connector X022 pins 1 & 8. The proper resistance range is 7.2 - 11.2 ohms . A. If there is no continuity, replace solenoid. B. If the coil is within specification, continue with Step 6 . 6. Use a multimeter to check for continuity between connector X022 pin 8 (harness side) and chassis ground. Flex the main frame (MF) harness between the signal valve and front frame ground #2 while making this check. A.
If there is no continuity to ground, there is an open circuit in the main frame (MF) harness between connector X022 pin 8 and the front frame ground #2 wire 1121 black or 600 black. Locate the open and repair. B. If there is continuity to ground, continue with Step 7 . 9665 1 27/05/2004 A.10.A / 8 3