DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM # 11 Control Pressure Pump Flow Test This test is used to determine the efficiency of the control pressure supply pump. The pump will wear internally over time. 2. Open the restriction valve on the flow rater completely. 3. Start and run the engine at LOW idle until you have verified the pressure on the flow rater, then increase engine speed to HIGH idle slowing while monitoring the system pressure. Test Procedure 1. Remove the supply hose that runs between the control pressure pump and the pressure filter base.
Connect the inlet hose from a flow rater to the control pressure pump and the outlet hose from the flow rater to the filter base. 4. The pump’s output should be above minimum specification. 5. Slowly turn in the flow raters restriction control to verify the systems relief valve, it should be above minimum system specification. CAUTION 6. The pump flow at approximately 21 bar (300 psi) below the relief valve setting should still be above minimum specification. Use extreme caution if this procedure is used. There is no relief valve in the system when testing in this manner. Be absolutely sure the flow meter restrictor is open when starting the combine engine.
Once the machine is started, increase to full throttle and VERY SLOWLY restrict the flowmeter NOT to exceed pressure specifications. If Flow Is Below Specifications 1. The pump could be worn excessively. 2. There could be problem with the PTO gearbox supply screen. A.10.A / 82