Case IH AFX8010 — ENGINE COOLANT SYSTEM

POWER PRODUCTION - ENGINE COOLANT SYSTEM 3. To gain further access to the stopcock, open the rotary screen access door in the cooler housing. 10034911 3 4. Install drain hose to stopcock and route to suitable container to collect coolant. Drain the coolant by opening stopcock at the bottom of the radiator. 10034869B 4 5. Flush the cooling system with clean water. Close stopcock, and fill the cooling system with clean water through the shunt tank filler opening . Start the engine and run it at low idle until the water temperature is at normal operating temperature. Stop the engine. Drain the water by opening stopcock . 6.

Remove hose, close stopcock and fill the cooling system with coolant as specified. 7. Install the cover. IMPORTANT: Always fill the cooling system with an approved fully formulated antifreeze/water mixture. Check the freezing point of the coolant after each refill. 10034862B 5 8. To fill the system with coolant be sure the stopcock is closed. 9675 1 27/05/2004 B.50.A / 13