Case IH AFX8010 — LUBRICATION SYSTEM

POWER PRODUCTION - LUBRICATION SYSTEM A. If there is continuity, the open circuit is in the Iveco engine harness between connector X197 pin 10 and connector X311 pin 2 on the brown wire. Locate the open and repair. B. If there is no continuity, continue with Step 7 . 7. Disconnect the engine (EN) harness from the main frame (MF) harness at connector X010 . Use a multimeter to check for continuity between the main frame (MF) harness end of connector X010 pin 14 and chassis ground. A. If there is continuity, the open circuit is in the engine (EN) harness between connector X010 pin 14 and connector X197 pin 10 wire 850 blue or 468 blue. Locate the open and repair. B.

If there is continuity, the open circuit is in the main frame (MF) harness between connector X010 pin 14 and connector X016 pin J2-14 wire 468 blue, 425 blue or 465 blue. Locate the open and repair. 8. Operate the machine while monitoring Universal Display Plus "DIAG" screen.. A. If no high out of range readings are indicated, erase the fault code and continue operation. 9676 1 27/05/2004 B.60.A / 20