POWER PRODUCTION - STARTING SYSTEM Engine starter - Testing (B.80.A.82 - G.40.A.20) AFX8010 9677 1 27/05/2004 B.80.A / 15 A-01 Iveco ECU E-36 Cold Start Indicator F-01 ECU Power Fuse F-28 Fuel Pump Fuse K-07 Fuel Pump Relay K-14 ECU Power Relay K-39 Grid Heater Relay M-23 Fuel Pump R-09 Engine Grid Heater N° Test Point Expected Result Other Result (Possible Cause) 1 Key Switch S-02 in the START position. Measure for 24 volts at B+ terminal of 24V starter. 24 volts If good reading, Go to test 6 Open circuit in the battery circuit. Go to test 2 2 Key Switch S-02 in the START position. Measure for 24 volts at front battery G-02 positive terminal.
24 volts Open circuit between 24V Starter B+ terminal and front battery G-02 positive terminal. Check continuity of cable and connections. Caution: When performing continuity tests on this circuit, ensure that the cable is disconnected from the positive battery terminal. Failure to do so could result in damage to the test meter. If there is no voltage, Go to test 3 3 Key Switch S-02 in the START position. Measure for 12 volts at 24V Start Relay K-38 terminal 31A. 12 volts Open circuit between 24V Start relay terminal 31A and front battery G-02 negative terminal. Check continuity of cable and connections. Caution:
When performing continuity tests on this circuit, ensure that the cable is disconnected from the battery terminal. Failure to do so could result in damage to the test meter. If there is no voltage, Go to test 4 4 Key Switch S-02 in the START position. Measure for 12 volts at 24V Start Relay K-38 terminal 30. 12 volts Open circuit between 24V Start Relay terminal 30 and terminal 31A. Remove battery cables and check continuity through energized relay. Replace 24V Start Relay. If there is no voltage, Go to test 5 5 Key Switch S-02 in the OFF position. Measure for 12 volts at the rear battery G-03 positive terminal.
12 volts Open circuit between 24V Start Relay terminal 30 and rear battery G-03 positive terminal. Check continuity of cable and connections. Caution: When performing continuity tests on this circuit, ensure that the cable is disconnected from the positive battery terminal. Failure to do so could result in damage to the test meter. If there is no voltage, there is an open circuit between rear battery G-03 negative terminal and chassis ground, or a failed Battery Switch S-52 (EU only). Check continuity of cables and connections. 6 Key Switch S-02 in the START position. Measure for 24 volts at 24V Starter motor M-29 terminal S. 24 volts Go to test 8 If there is no voltage, Go to test 7