POWER PRODUCTION - STARTING SYSTEM Start control Start switch - Testing (B.80.A.90.82 - G.40.A.20) AFX8010 Start control Start switch - Testing (B.80.A.90.82 - G.40.A.20) AFX8010 9677 1 27/05/2004 B.80.A / 16 N° Test Point Expected Result Other Result (Possible Cause) 7 Key Switch S-02 in START position. Measure for 24 volts at 24V Start Relay K-38 terminal 50. 24 volts Open circuit in engine (EN) harness between 24V Start Relay terminal 50 and 24V Starter motor M-29 wire 834 white/black. Check continuity of cable and connections. If there is no voltage, Go to test 8 8 Key Switch S-02 in START position. Measure for 24 volts at 24V Start Relay K-38 terminal 30A.
24 volts Open circuit between 24V Start Relay terminal 50 and terminal 30A. Remove battery cables and check continuity through energized relay. Replace 24V Start Relay. Open circuit between 24V Start relay terminal 30A and front battery G-02 positive terminal. Check continuity of cable and connections. Caution: When performing continuity tests on this circuit, ensure that the cable is disconnected from the battery terminal. Failure to do so could result in damage to the test meter. 9 Key Switch in OFF position. Measure resistance from 24V starter M-29 case to chassis ground. Less than 1 ohms If good reading, Go to test 9 Check contact surface of 24V Starter with engine.
Ensure 24V Starter is mounted securely. Check ground strap between engine and chassis. 10 Set multimeter to read VOLTAGE. Attach positive lead to battery positive terminal. Attach negative lead to B+ terminal of 24V Starter. Turn key to START position. Check Voltage. If less than 0.4 volts shown, and 24V Starter does not operate, replace 24V Starter. More than 0.4 volts indicated on multimeter, replace cable between positive battery terminal and 24V Starter B+ terminal. N° Test Point Expected Result Other Result (Possible Cause) 1 Measure for 12 volts at key switch connector X068 (pin1). 12 volts If good reading, go to the next test point.
Open circuit 053 (RD) between fuse F-38 and Key Switch connector X068 (pin 1). Go to next test 2 Key Switch in "IGN/ACC" position. Measure for 12 volts at key switch connector X068 (pin 6 and 4). 12 volts If good reading, go to the next test point. Key Switch 3 Key Switch in "START" position Measure for 12 volts at key switch connector X068 (pin 2). 12 volts If good reading, Key Switch operating normally. Key Switch N° Test Point Expected Result Other Result (Possible Cause) 1 Remove the electrical connector from the Key Switch S-02. While holding the Key Switch in the "START" position, check for continuity between (pins 1 and 2). Continuity Go to test 2 If no continuity, replace Key Switch.
2 While holding the Key Switch in the "START" position, check for continuity between (pins 1 and 6). Continuity Go to test 3 If no continuity, replace Key Switch.