POWER PRODUCTION - STARTING SYSTEM Start control Safety switch - Testing (B.80.A.90.81 - G.40.A.20) AFX8010 Start control Start relay - Testing (B.80.A.90.80 - G.40.A.20) AFX8010 9677 1 27/05/2004 B.80.A / 17 N° Test Point Expected Result Other Result (Possible Cause) 3 While holding the Key Switch in the "IGN/ACC" position, check for continuity between (pins 1 and 6). Continuity Go to test 4 If no continuity, replace Key Switch. 4 While holding the Key Switch in the "IGN/ACC" position, check for continuity between (pins 1 and 4). Continuity Go to test 5 If no continuity, replace Key Switch. 5 While holding the Key Switch in the "ACC" position, check for continuity between (pins 1 and 4).
Continuity Go to test 6 If no continuity, replace Key Switch. 6 While holding the Key Switch in the "OFF" position, check for continuity between (pin 1) and (pins 2, 4, 6). No Continuity If good reading, Key Switch is operating normally. If no continuity, replace Key Switch. N° Test Point Expected Result Other Result (Possible Cause) 1 Key Switch in "IGN" position Measure for 12 volts at connector X059 (Pin 1). 12 volts If good reading, Go to test 2 Open circuit 300 (OR) or 108 (OR) between fuse F-48 and Neutral Switch connector X059 (Pin 1). Blown fuse F-48 (Refer to Power Distribution - Testing) 2 Place Neutral Switch in the CLOSED position.
Measure for 12 volts at Neutral Switch connector X059 (pin 3). 12 volts If good reading, Go to test 3 Neutral Switch 3 Place Neutral Switch in the OPEN position. Measure for 12 volts at Neutral Switch connector X059 (pin 2). 12 volts If good reading, Neutral Switch functioning properly. Neutral Switch N° Test Point Expected Result Other Result (Possible Cause) 1 Place Key Switch in the START position. Measure for 12 volts at Key Switch connector X199(pin 86). 12 volts If good reading, Go to test 2 Open circuit 092 (WH) between Start Relay connector X199 (pin 86) and Neutral Start Relay (pin 5). Check in-line connectors X005 (pin 6) and X010 (pin 5) for connection.
2 Measure for 12 volts at Start Relay (pin 30). 12 volts If good reading, Go to test 4 Open circuit 801 (RD) from Start Relay (pin 30) to 12V starter B+ terminal. Faulty 12V Battery Switch. Go to next test point 3 Measure for 12 volts at 12V Starter B+ terminal. 12 volts If good reading, Repair open in 801 (RD) circuit. Open B+ circuit between 12 System Batteries and 12 V Starter. Faulty 12V Battery Switch. 4 Key Switch in OFF Position. Measure resistance from Start Relay connector X199 (pin 85) to ground. Less than 1 ohms If good reading, Go to test 5 Open circuit 800 (BK) from start relay to ground. 5 Key Switch in OFF position. Measure for 12 volts at Start Relay (pin 87).
12 volts If good reading, Start Relay is operating properly. Start Relay