POWER PRODUCTION - STARTING SYSTEM Start control Neutral start relay - Testing (B.80.A.90.84 - G.40.A.20) AFX8010 Start control 24V start relay - Testing (B.80.A.90.85 - G.40.A.20) AFX8010 9677 1 27/05/2004 B.80.A / 18 N° Test Point Expected Result Other Result (Possible Cause) 1 Key switch in the START position. Measure for 12 volts at Neutral Start Relay (pin1). 12 volts If good reading, Go to test 2 Perform Start control Safety switch - Testing (B.80.A.90.81 - G.40.A.20). 2 Key Switch in the START position. Measure for 12 volts at Neutral Start Relay (pin3).
12 volts If good reading, Go to test 4 Open or short to ground in circuit 91 (OR) between Key Switch connector X068 (pin2) and Neutral Start Relay (pin3). A short to ground will blow Fuse F-38. Go to next test point. 3 Measure for 12 volts at Key Switch connector X068 (pin2). 12 volts If good reading, repair open in 91 (OR) circuit between Neutral Start Relay (pin 1) and Key Switch Connector X068 (pin 2). Open in unswitched B+ circuit. Perform Start control Start switch - Testing (B.80.A.90.82 - G.40.A.20) Key Switch Perform Start control Neutral start relay - Testing (B.80.A.90.84 - G.40.A.20) 4 Key Switch in the OFF position. Measure resistance from Neutral Start Relay (pin 2) to ground.
12 volts If good reading, Go to test 5 Open in circuit 094 (BK) between Neutral Start Relay (pin 2) and ground. 5 Key Switch in OFF position. Measure for 12 volts at Neutral Start Relay (pin 5). 12 volts If good reading, Neutral Start Relay operating properly. Neutral Start Relay N° Test Point Expected Result Other Result (Possible Cause) 1 Key Switch in START position. Measure for 12 volts at 24V Start Relay (pin 50A). 12 volts If good reading, Go to test 2 Open circuit 804 (WH) between 24V Start Relay (pin 50A) and Start Relay (pin 87). Go to test 2 2 Measure for 12 volts at 24V Start Relay (pin 87).
12 volts If good reading, Go to test 3 Open circuit 804 (WH) between 24V Start Relay (pin 50A) and Start Relay (pin 87). 3 Measure for 24 volts at 24V Start Relay (pin 30A). 24 volts If good reading, Go to test 4 Open circuit 832 (RD) between 24V System Batteries and 24V Start Relay (pin 30A). Faulty 24V Battery Switch. 4 Key Switch in OFF position. Measure for resistance from 24V Start Relay (pin 50). Less than 1 ohms If good reading, Go to test 5 Open circuit 833 (BK) between 24V Start Relay and Ground. 5 Key Switch in START position. Measure for 24 volts at 24V Start Relay (pin 50). 24 volts If good reading, Go to test 6 24V Start Relay 6 Measure for 12 volts at 24V Start Relay (pin 30).
12 volts If good reading, Go to test 7 Open circuit between 24V System Batteries and 24V Start Relay (pin 30). Faulty 24V Battery Switch. 7 Measure for 12 volts at 24V Start Relay (pin 31A). 12 volts If good reading, Go to the next test point. 24V Battery Switch. 24V Start Relay.