POWER PRODUCTION - STARTING SYSTEM Start control Safety switch - Short circuit to B+ (B.80.A.90.81 - G.30.B.54) AFX8010 E0164-03 - Ground Drive Hydro Voltage Supply Cause: The Ground Drive Hydro Voltage Supply circuit is shorted to a higher than normal voltage source. Possible failure modes: 1. Supply wiring shorted to greater than 18.0 volts . 2. Faulty alternator/regulator. 3. Controller internal failure (internal regulator failure). Solution: 1. Start the combine. Engage the park brake, and shift the transmission into neutral (N). Enter the Universal Display Plus "DIAG" screen. Select the "GROUND DRIVE" sort menu, and select "HYDRO VOLT" to check the voltage range.
Carefully move the propulsion handle (MFH) forward and reverse from neutral and check voltage range. The proper voltage supply is 10.0 - 18.0 volts with the propulsion handle (MFH) out of the neutral position. A. If the voltage reading is high out of range ( 18 volts or more), continue with Step 2 . B. If the voltage reading is within the proper limits, the shorted wire may not be powered up at this time. Continue the troubleshooting at Step 5 . 2. Shut off the combine engine, and then turn the key switch on again. Enter the Universal Display Plus "DIAG" screen. Select the "GROUND DRIVE" sort menu, and select "HYDRO VOLT" to check the voltage range.
Carefully move the propulsion handle (MFH) forward and reverse from neutral and check voltage range. The proper voltage supply is 10.0 - 18.0 volts with the propulsion handle (MFH) out of the neutral position. A. If the voltage reading is between 10 and 18 volts , the alternator and/or regulator has failed, and is producing excessive voltage. Refer to Alternator - Problem solving (A.30.A.82 - G.40.A.30) for additional alternator testing information. B. If the voltage is greater than 18 volts , continue with Step 3 . 3. Key switch in the "Off" position. Check the voltage at fuse F42 using a multi-meter. A.
If the voltage reading is greater than 18 volts , then there is a fault in the wiring of the 24V starting system. Refer to STARTING SYSTEM - Problem solving (B.80.A - G.40.A.30) for additional information. B. If the voltage reading is between 10 and 18 volts , continue with Step 4 . 4. Key switch in the "On" position. Position the propulsion handle (MFH) out of neutral. Remove the buddy seat and storage bin to gain access to connector X015 on CCM2. Check the voltage at connector X015 pin J1-17. A. If the voltage reading is greater than 18 volts , then a high voltage source has been connected to one of the following wires:
- wire 108 orange, fuse F48 through connector X001 pin 3 to RH harness splice - RH console power wires to propulsion handle S-03, front switch panel A-13, rear switch panel A-18 and RHM connector X026 pins 4 & 5 - wires 300 orange, 110 orange & 1180 orange, RH harness splice across separator switch S-30 to neutral switch S-02 connector X059 pin 3 - wire 113 yellow, neutral switch S22 through connector X001 pin 17 to CCM2, pin J1-17. 9677 1 27/05/2004 B.80.A / 19