Case IH AFX8010 — PRIMARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM Sensing system Temperature sensor - Open circuit (A.10.A.95.90 - G.30.B.50) AFX8010 E0024-05 - Hydraulic Reservoir Temperature Sensor Cause: The hydraulic oil reservoir temperature sensor (B-18) circuit is open. Possible failure modes: 1. Sensor supply wiring is open. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "HYDRAULIC" sort menu, and select "RES TEMP SEN" to check the voltage range. The normal operating range for the sensor is 0.5 - 4.9 volts . If there is an open in the supply or ground wiring, the voltage will be 4.9 - 5.2 volts . A.

If the voltage reading is high 4.9 - 5.2 volts , continue with Step 2 . B. If the voltage reading is within the proper limits, the open is not present at this time. Continue the troubleshooting at Step 7 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect the hydraulic oil reservoir temperature sensor connector X103 . Use a jumper wire to short the harness end of connector X103 pin B to chassis ground. A.

If the voltage drops to 0 - 0.5 volts indicating a ground, the open circuit is not in the supply side of the circuit. Continue with Step 4 . B. If the monitor still displays 4.9 - 5.2 volts , continue with Step 3 . 3. Disconnect the gearbox (GB) harness from the main frame (MF) harness at connector X011 . Use a jumper wire to short connector X011 pin 5 to chassis ground. A. If the voltage drops to 0 - 0.5 volts indicating a ground, the open circuit is in the gearbox (GB) harness between connector X011 pin 5 and connector X103 pin B wire 446 yellow. Locate the open and repair. B.

If the monitor still displays 4.9 - 5.2 volts , the open circuit is in the main frame (MF) harness between connector X011 pin 5 and connector X019 pin J2-24 wire 446 yellow. Locate the open and repair. 4. Disconnect the hydraulic oil reservoir temperature sensor connector X103 . Use a multimeter to check for continuity between the harness end of connector X103 pin A and chassis ground. A. If there is continuity, the ground path for the sensor is complete, and the fault is in the sensor itself. Replace the sensor. B. If there is no continuity to ground, the ground path for the sensor is open. Continue with Step 5 . 5.

Disconnect the gearbox (GB) harness from the main frame (MF) harness at connector X011 . Use a multimeter to check for continuity between the harness end of connector X011 pin 8 and chassis ground. A. If there is continuity, the open circuit is in the gearbox (GB) harness between connector X011 pin 8 and connector X103 pin A wire 480 blue or 488 blue. Locate the open and repair. 9665 1 27/05/2004 A.10.A / 9 6