Case IH AFX8010 — SECONDARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - SECONDARY HYDRAULIC POWER SYSTEM Sensing system Pressure sensor - Under limit value (A.12.A.95.91 - G.30.C.20) AFX8010 E0162-01 - PTO Control Pressure Sensor Context: When the control oil pressure drops below 1827 kPa ( 265 psi ) for more than 2 seconds after the engine has been running for at least 3 seconds, the alarm message "A0012 Control Pressure LOW" will be displayed to the operator. If the oil pressure drops below 1724 kPa ( 250 psi ), the alarm will be displayed, and the engine will be shutdown within 7 seconds to prevent damage to the hydraulic systems. When the alarm message is displayed, a permanent record is created in the error history. Cause:

The "A0012 Control Pressure LOW" alarm has occurred at least once on the vehicle. Possible failure modes: 1. The control pressure has dropped below acceptable limits during vehicle operation. Solution: 1. This error message appears as a permanent record that a low control pressure condition has occurred on the combine, and cannot be erased using the combine display controls. The EST must be used to erase this fault code. A. If this fault code appears, remove and inspect the PTO gearbox oil for indication of internal damage. 9666 1 27/05/2004 A.12.A / 6