Case IH AFX8010 — SECONDARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - SECONDARY HYDRAULIC POWER SYSTEM Sensing system Pressure sensor - Short circuit to B+ (A.12.A.95.91 - G.30.B.54) AFX8010 E0162-03 - PTO Control Pressure Sensor Cause: The control pressure sensor (B-35) circuit is shorted to 12 volts. Possible failure modes: 1. Switch supply wiring shorted to 12 volts . 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "HYDRAULIC" sort menu, and select "CNTL PRESS SEN" to check the voltage range. The proper voltage range for the control pressure sensor (key On, engine OFF) is - 0.5 - 2.8 volts .

The proper voltage range for the control pressure sensor (key On, engine Running) is - 2.8 - 4.9 volts . A. If the voltage reading is high out of range (> 5.2 volts ), continue with Step 2 . B. If the voltage reading is normal, the shorted wire may not be energized at this time. Continue with Step 7 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect the control pressure sensor connector X098 .

Use a multimeter to check for voltage on connector X098 pin B. There should be 5 volts present. A. If high (> 5.5 volts ) voltage is found, the regulated voltage supply is incorrect. The error " E0165-03 - CCM2 J2 5V Reference " should be listed in the Universal Display Plus "ERROR" screen. Correct that error, and then check to determine if this error has been resolved. B. If correct voltage is found, continue with Step 3 . 3. Disconnect the control pressure sensor connector X098 . Use a multimeter to check for continuity between connector X098 pin A and chassis ground. A. If continuity is found, continue with Step 5 . 4.

Disconnect the gearbox (GB) harness from the main frame (MF) harness at connector X011 . Use a multimeter to check for continuity between the harness end of connector X011 pin 22 and chassis ground. B. If no continuity is found, continue with Step 4 . A. If there is continuity, there is an open circuit in the gearbox (GB) harness between connector X011 pin 22 and connector X098 pin A wire 683 blue. Locate the open and repair. B. If there is continuity, the open circuit is in the main frame (MF) harness between connector X011 pin 22 and connector X016 pin J2-14 wire 683 blue, 425 blue or 465 blue. Locate the open and repair. 5. Disconnect the control pressure sensor connector X098 .

Use a multimeter to check for voltage on connector X098 pin C. A. If no voltage is found, continue with Step 7 . B. If high (> 5.2 volts ) voltage is found, continue with Step 6 . 9666 1 27/05/2004 A.12.A / 7