Case IH AFX8010 — SECONDARY HYDRAULIC POWER SYSTEM

DISTRIBUTION SYSTEMS - SECONDARY HYDRAULIC POWER SYSTEM Sensing system Pressure sensor - Open circuit (A.12.A.95.91 - G.30.B.50) AFX8010 E0162-05 - PTO Control Pressure Sensor Cause: The control pressure sensor (B-35) circuit is open or shorted to ground. Possible failure modes: 1. Sensor signal wiring open or shorted to ground. 2. Loss of power to sensor. 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "HYDRAULIC" sort menu, and select "CNTL PRESS SEN" to check the voltage range. The proper voltage range for the control pressure sensor (key On, engine OFF) is 0.5 - 2.8 volts .

The proper voltage range for the control pressure sensor (key On, engine Running) is 2.8 - 4.9 volts . A. If the voltage reading is low out of range ( 0.3 volts ), continue with Step 2 . B. If the voltage reading is normal, the shorted wire may not be open or grounded at this time. Continue with Step 9 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect the control pressure sensor connector X098 .

Use a multimeter to check for voltage on connector X098 pin B. There should be 5 volts present. A. If no voltage is found, continue with Step 3 . 3. Disconnect the gearbox (GB) harness from the main frame (MF) harness at connector X011 . Use a multimeter to check for voltage on connector X011 pin 21. There should be 5 volts present. B. If correct voltage is found, continue with Step 5 . A. If voltage is found, there is an open circuit in the gearbox (GB) harness between connector X098 pin B and connector X011 pin 21 wire 486 pink. Locate the open and repair. B. If no voltage is found, continue with Step 4 . 4.

Carefully disconnect the main frame (MF) harness from the CCM2 module at connector X016 . Use a multimeter to check for voltage on the CCM2 module connector X016 pin J2-31. There should be 5 volts present. A. If voltage is found, there is an open circuit in the main frame (MF) harness between connector X011 pin 21 and connector X016 pin J2-31 wire 459 pink or 486 pink. Locate the open and repair. B. If no voltage is found, there is an internal fault with the CCM2 module. Replace the module. 5. Disconnect the control pressure sensor connector X098 . Use a multimeter to check for continuity between connector X098 pin C and chassis ground. A. If continuity is found, continue with Step 6 . B.

If no continuity is found, continue with Step 7 . 9666 1 27/05/2004 A.12.A / 12