Case IH AFX8010 — TRANSMISSION Hydrostatic

POWER TRAIN - TRANSMISSION Hydrostatic Relief valve - Pressure test (C.20.F.16 - F.40.A.30) AFX8010 Relief valve - Pressure test (C.20.F.16 - F.40.A.30) 1. The hydrostatic system high pressure is determined by the two multifunction valves. The relief valve setting is 450 bar (6525 psi) . The pressure limiter will start to destroke the pump servo cylinders at 420 bar (6090 psi) . 2. The high pressure can be checked at pump test ports M1, (1) , for forward, and test port M2, (2) , for reverse. A test coupler is installed in both ports from the factory. The pressure can also be checked at the drive motor; forward high pressure at test port M1 and reverse high pressure at test port M2.

CAUTION 46-77A - Before you do service under the machine, put the machine on a level surface, engage the parking brake and stop the engine. Put blocks at the front and rear of the tires. Failure to follow these instructions can cause injury. 10033622A5 1 3. With the gauges installed put the transmission in 4th gear, start and run the engine at high idle, hold the brake pedals down and move the hydrostatic control lever forward, then rearward. Record pressure gauge readings. Only hold the system in the overpressure situation for a few seconds and return to neutral as soon as possible. Both forward and reverse should indicate a reading of approximately 456 bar (6612 psi) . NOTE:

Refer to Pump - General specification (C.20.F.20 - D.40.A.10) "High Pressure - Forward Pressure" and "High Pressure - Reverse Pressure" for more information. CAUTION M142A - Never operate the engine in a closed building. Proper ventilation is required under all circumstances. 9681 1 27/05/2004 C.20.F / 21