POWER TRAIN - TRANSMISSION Hydrostatic Control valve - Unidentified failure (C.20.F.13 - G.30.B.46) AFX8010 E0202-11 - Ground Drive Hydro Cause: The ground speed hydrostat valve L-23 circuit is shorted to ground. Possible failure modes: 1. Supply wiring damaged. 2. Solenoid failed. 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "GROUND DRIVE" sort menu, and select "HYDRO" to check the voltage range. Move the propulsion handle to the full forward position, the full rearward position, and back to the neutral position while monitoring the voltage.
With the propulsion handle in neutral, the voltage indicated should be 0 volts . With the propulsion handle in the full rearward position, the voltage indicated should be approximately 2.5 volts . The voltage should increase progressively with handle position. When moving the handle out of neutral, if the voltage spikes to maximum (> 4.7 volts ), and then abruptly drops to 0 volts , there is a short to ground on the output lead to the control valve. With the propulsion handle in the full forward position, the voltage indicates should be approximately 4.4 volts . A. If the voltage spikes to maximum (> 4.7 volts ), and then abruptly drops to 0 volts , continue with step 2 . B.
If the voltage readings are within the proper ranges, continue with step 10 . 2. Turn the key switch to the "OFF" position. Disconnect the ground speed hydrostat valve connector X100 . Use a multimeter to check the resistance of the ground speed hydrostat valve coil between terminals D & C, and then between terminals A & B. The proper resistance range for the ground speed hydrostat valve coils is 16k - 20k ohms . A. If either of the solenoid coils is out of specification, replace the solenoid. 3. Use a multimeter to check for continuity between the ground speed hydrostat valve coil terminals D or C and chassis ground. There should not be continuity to ground. B.
If the solenoid coils are within specifications, continue with step 3 . A. If there is continuity to ground, replace the solenoid. B. If there is no continuity to ground, continue with step 4 . 4. Use a multimeter to check for continuity between the harness end of connector X100 pin D and chassis ground. There should not be continuity to ground. A. If there is continuity to ground, continue with step 5 . B. If there is no continuity to ground, continue with step 7 . 5. Disconnect connector X011 . Use a multimeter to check for continuity between the main frame (MF) harness end of connector X011 pin 16 and chassis ground. There should not be continuity to ground. A.
If there is no continuity to ground, there is a short to ground in the gearbox (GB) harness between connector X011 and connector X100 wire 880 white.Locate the short and repair. B. If there is continuity to ground, continue with step 6 . 9681 1 27/05/2004 C.20.F / 28