Case IH AFX8010 — ELECTRICAL POWER SYSTEM

DISTRIBUTION SYSTEMS - ELECTRICAL POWER SYSTEM INTRODUCTION TO TROUBLESHOOTING IMPORTANT : Use of powered test lights or any 12 volt source to test or activate electrical circuits may result in internal failure of the computer modules. Never apply a 12 volt source directly to a solenoid or other device to prevent damage to the combine electrical system. Fault Codes and Fault Finding Troubleshooting and fault finding of the electrical system should always be carried out in a logical and planned sequence. Many apparent faults associated with electronic components are often hastily diagnosed and result in the replacement of expensive components.

An extra few minutes confirming the apparent fault will result in a more positive and cost effective repair. The AFX combines have a built in diagnostic capabilities to assist the operator and service technician to identify and locate the source of electrical system concerns. The Universal Display Plus monitor is used to indicate, in coded format, any malfunction detected in the electrical and electronic systems. Two different coded formats are used to indicate concerns; alarms and errors. An alarm is an indication of some mechanical condition on the vehicle, and alerts the operator to perform necessary maintenance, or to change operating conditions to correct the alarm condition.

Examples of alarms would be to indicate an engine overheat condition, blocked filters, or improper control operation. Alarms are not used to indicate faults with electrical circuits. An error is an indication of a fault with an electrical circuit or component, and alerts the operator that the circuit or component is no longer functioning. Examples of error messages include open circuits, shorts to ground, or short to high voltage. These errors are typically the result of wire harness damage, or sensor misadjustment or failure. When investigating an electrical concern, the first step is to fully understand the problem.

Get a clear description of the concern from the operator, and if possible, operate the vehicle to confirm the problem. Once the problem is clearly identified, use the “Diag” screens of the Universal Display Plus monitor to determine if any alarm or error messages exist that relate to the problem. If related error messages are found, diagnostic screens showing voltage, current or frequencies for that specific circuit are available to assist in pinpointing the source of the problem. In most cases, circuit testing may be accomplished using only the on-board diagnostic capabilities. Diagnostic procedures for each error code are detailed in this manual.

Where the fault finding procedure requires checks for continuity, a visual inspection of the wiring should be made prior to conducting any test to ensure that obvious ‘mechanical’ damage has not occurred to the harness or connectors. In some cases, use of a multimeter will be necessary to locate the source of the fault. A good quality multimeter, capable of measuring voltage, current, and resistance of at least 20,000 ohms, is an essential item to perform fault finding. When using a multimeter, it is good practice to select a high range and work downwards to avoid damaging the instrument.

Refer to the Operator’s manual supplied with the meter, and to the ‘Basic Multimeter Use” section of this chapter for further details. IMPORTANT : Care should be taken when using the multimeter. Use the instrument only as instructed to avoid damage to the internal elements of the microprocessors on the combine. When checking the continuity of wiring, sensors or switches, it is necessary to isolate the combine modules and ensure the key switch is turned off to prevent possible further damage. The key switch should only be switched on and the combine modules connected where specifically instructed in the fault finding procedure.

During fault finding, it will often be necessary to uncouple connectors for inspection, or to provide access for testing. When using the combine on-board diagnostics, uncoupling connectors as directed in the fault finding procedures will often be necessary to locate the source of the fault. Unless specifically noted, connectors should not be back-probed using test spoons or other tools, to prevent damage to the connector and wire seals. CAUTION Never couple or uncouple electrical connectors while the engine is running, to prevent machine damage and personal injury due to electrical shock.

WARNING To avoid personal injury, never attempt to access electrical connectors under the cab while the engine is running. Accidental contact with the feeder angle sensor or inappropriate access to the electrical circuits to the modules may cause the feeder to move unexpectedly, resulting in personal injury or death. IMPORTANT : The under-cab connectors to the chassis control modules (CCM’s) do not normally need to be accessed for diagnostic purposes. Repeated coupling and uncoupling of these connectors will result in seal and connector damage, causing electrical circuit failures. If it is found necessary to clean the connectors a con- tact spray should be used.

DO NOT USE ANY OTHER METHOD FOR CLEANING TERMINALS. Do not use a cleaner that contains Trichloro-ethylene, this solvent will damage the plas- tic body of the connector. A.30 / 5E