DISTRIBUTION SYSTEMS - ELECTRICAL POWER SYSTEM ELECTRICAL TEST PROCEDURE 4: CONTINUITY TEST - CHECK FOR OPEN CIRCUITS CONDITIONS FOR PERFORMING CONTINUITY TESTS: 1. Keyswitch OFF (sometimes disconnect battery or pull fuses). 2. Connectors at both ends of the circuit disconnected. All other connectors must be reconnected to perform test. 3. Set meter to measure resistance or ohms, and measure circuit resistance as illustrated. Use the red meter lead to touch the connector pins, one pin at a time, and avoid contact with the case of metal connectors. Use the black lead to make contact with the connector pin at the other end of the circuit.
Avoid contact with other pins in the connector and the connector case, if it is metal. 4. Determine if measured resistance falls within guidelines specified in the procedure. If the resistance is no more than 3 to 4 ohms, the circuit is continuous. More resistance usually indicates dirty or corroded terminals in connectors, and 100K ohms or greater indicates an open circuit. 21 A.30 / 5N