Case IH AFX8010 — ELECTRICAL POWER SYSTEM

DISTRIBUTION SYSTEMS - ELECTRICAL POWER SYSTEM The solenoid plunger may have different uses: the most common are moving a hydraulic spool or a mechanical lever. The MOST COMMON FAULTS that can occur are: Short circuit winding: if a section of the winding allows the current to pass directly from positive (+) to negative (-) terminals without passing through the winding, this will cause the relevant circuit fuse to blow. Broken winding: causing an open circuit, it will not allow the current to pass through the winding, so the solenoid will not operate. Seized plunger (and/or connected components): the solenoid will only move the plunger if all components are free to move.

PWM SOLENOID VALVES Whenever it is necessary to provide proportional control to the solenoid valves, it is much better to use a principle of operation called pulse width modulation (PWM). PWM is a variable DC voltage signal that is used to control the solenoid valves. The voltage signal is pulsed on and off many times a second (at a constant frequency of 500 Hz) at a constant supply voltage of 12 V. 35 A.30 / 5U