DISTRIBUTION SYSTEMS - ELECTRICAL POWER SYSTEM The CCM modules contain transistors that are supplied with a constant input voltage which is switched on and off to achieve the variable input range. In this way the control module is able to limit the armature movement, so the hydraulic output flow of the solenoid is proportional to the average DC voltage. The lower voltage also allows the solenoid to operate with less residual magnetism and so the entire circuit will operate smoother. The variable DC voltage signal level is determined by varying the duration of the ON pulse relative to the OFF pulse.
The ratio between the ON time and the cycle time is called duty cycle and is stated as a percentage of one complete cycle. Diagrams, 1 to 3, show the normal operating range of the PWM valve, and diagram 4, shows the initial 12V programming and fill time only. The diagrams in column A show the voltage signal that is sent to the valve, whereas column B shows the relevant spring pressure and column C the reading on a voltmeter connected to the solenoid valve. Diagram, 1, shows the OFF position: no signal is directed to the valve, which means no spring pressure in the valve at all and results in a zero voltage reading.
Increasing the duty cycle causes some pressure to be made on the circuit (Diagram 2), which results in a voltmeter reading increase. Diagram, 3, shows the maximum signal that is used during the normal activity of the valve: its duty cycle is around 0.5, which results in a spring pressure for the half of its run and in an indication of a 6 volt average DC current. 36 The electrical circuit to the solenoids can be checked by using a digital or analogue DC voltmeter, which will indicate the average voltage readings. A.30 / 5V