Case IH AFX8010 — USER PLATFORM

BODY AND STRUCTURE - USER PLATFORM POWER MIRROR SYSTEM SYMPTOM CHART NOTE: The batteries must be fully charged and all connections clean and tight. Use a multimeter (DVOM) for these tests. For battery testing and service, see the battery section in the service manual. DO NOT use a self-powered test light for any of these tests. Use of a self-powered test light can cause damage to components in this system. CAUTION WARNING Before performing any of the electrical tests, be sure all operating controls are in neutral or park lock position. This will eliminate accidental movement of the machine or start-up of power driven equipment.

E.34 / 19 Symptom Possible Cause Reference/Test All Power Mirrors inoperable No power or ground to Mirror Adjust Switch S-27 A - Mirror Adjust Switch Test Mirror Adjust Switch S-27 RH and German Power Mirrors inoperable Mirror Adjust Switch S-27 A - Mirror Adjust Switch Test Mirror Select Switch S-27 B - Mirror Select Switch Test Left Power Mirror inoperable Mirror Adjust Switch S-27 A - Mirror Adjust Switch Test steps 4-7 and 12-15.

Left Mirror Assembly C - LH Power Mirror Test Right Power Mirror inoperable Right Mirror Assembly D - RH Power Mirror Test Adjacent circuits German Power Mirror inoperable German Mirror Assembly E - German Power Mirror Test Adjacent circuits All Heated Mirrors inoperable Mirror Heat Switch S-19 F - Mirror Heat Switch Test No general power or ground supply for heating mirrors G - Heating Mirrors Test steps 1 and 2 LH Heated Mirror inoperable Heating element for LH Mirror G - Heating Mirrors Test steps 1 and 2 Adjacent circuits RH Heated Mirror inoperable Heating element for RH Mirror G - Heating Mirrors Test steps 3 and 4 Adjacent circuits German Heated Mirror inoperable Heating element for German Mirror G - Heating Mirrors Test steps 5 and 6 Adjacent circuits