BODY AND STRUCTURE - USER PLATFORM E.34 / 30 Test Point Good Reading Possible Cause of Bad Reading 4 Check the resistance between RH Mirror R-10 (pin 6) and ground. Less than 1 ohm If good reading, and RH Mirror Heat R-10 doesn’t work replace the RH Mirror assembly. Go to next test point if RH Mirror Heat R-10 was not defective. Open in circuit 670 (BK) or 295 (BK) between RH Mirror R-10 (pin 6) and ground. Check the X121 (pin 6) and X036 (pin 12) in-line connectors for connection. 5 Check the voltage at German Mirror R-14 (pin 3). 12 volts If good reading, go to next test point.
Open in circuit 862 (OR) or 931 (OR) between German Mirror R-14 (pin 3) and Mirror Heat Switch S-19 connector X127 (pin 3). 6 Check the resistance between German Mirror R-14 (pin 6) and ground. Less than 1 ohm If good reading, and German Mirror Heat R-14 doesn’t work replace the German Mirror assembly. Open in circuit 863 (BK) or 295 (BK) between German Mirror R-14 (pin 6) and ground. Check the X287 (pin 6) and X036 (pin 12) in-line connectors for connection.