TOOL POSITIONING - LIFTING Command valve Header lift valve - Unidentified failure (G.10.A.12.20 - G.30.B.46) AFX8010 E0056-11 - Header Raise Valve Cause: The header raise valve (L-11) circuit is open, or shorted to ground. Possible failure modes: 1. Supply wiring damaged. 2. Bad solenoid. 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "HDR HEIGHT/TILT" sort menu, and select "RAISE VLV" to monitor the current flow. Use the "COMMAND" and "ENGAGE" functions to power the circuit at 100% output. The proper current is approximately 1.0 - 1.5 amps . A.
If the current reading goes to maximum, and then back to zero, the circuit is shorted to ground and the software has shut off the output to protect the module and wiring. Continue with Step 2 . B. If the reading is 0 amps , the circuit is open. Continue with Step 7 . 2. Disconnect connector X022 . Use a multimeter to check the resistance of the header raise valve coil (L-11) between connector X022 pins 4 & 6. The proper resistance range is 3 - 5 ohms . C. If the reading is within the proper range, the circuit is working properly. Continue with Step 9 . A. If there is zero resistance, the header raise solenoid is shorted internally. Replace the solenoid. B.
If there is infinite resistance, the header raise solenoid is open. Replace the solenoid. C. If the resistance is correct, continue with Step 3 . 3. Use a multimeter to check for continuity between connector X022 pin 4 (MF harness side) and chassis ground. Flex the main frame (MF) harness while making this check. A. If there is continuity to ground, there is a short to ground in the main frame (MF) harness between connector X022 and connector X019 pin J2-4 wire 1112 white. Locate the short and repair. B. If there is no continuity to ground, continue with Step 5 . 4. Use a multimeter to check for continuity between connector X022 pin 6 (harness side) and chassis ground.
Flex the main frame (MF) harness while making this check. A. If there is no continuity to ground, continue with step 6 . B. If there is continuity to ground, continue with Step 7 . 5. Carefully disconnect connector X019 on the bottom of CCM1 module. Use a multimeter to check for continuity between connector X019 pin J2-20 on the module and chassis ground. A. There is infinite resistance. The sense resistor in the CCM1 module has failed. Replace the module. B. There is less than 1 ohms resistance, indicating the sense resistor in the CCM2 module is okay.
There is an open circuit in the main frame (MF) harness between connector X022 pin 6 and connector X019 pin J2-20 wire 1117 black or 1114 black. Locate the open and repair. 9706 1 27/05/2004 G.10.A / 14