Case IH AFX8010 — LIFTING

TOOL POSITIONING - LIFTING Sensing system Left tool position sensor - Open circuit (G.10.A.95.82 - G.30.B.50) AFX8010 E0020-05 - Left Header Height / Tilt Sensor Cause: The left height/tilt sensor (R-12) circuit is open or has lost supply voltage. Possible failure modes: 1. Sensor signal wiring is open. 2. Loss of power to the sensor. 3. Module internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "HDR HEIGHT/TILT" sort menu, and select "LEFT SEN" to check the voltage range.

Manually raise and lower the header against the ground several times while monitoring the voltage; the voltage should stay within range, and should change smoothly with header sense plate movement. The proper voltage range for a properly adjusted sensor is 0.2 - 4.7 volts . A. If the voltage reading is low ( 0.2 volts ) out of range, continue with Step 2 . B. If the voltage reading is within the proper limits, the circuit may not be open or shorted to ground at this time. Continue the troubleshooting at Step 8 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed.

Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect connector X305, and use a multimeter to test for voltage on connector X305 pin 1. There should be 5 volts present. A. If 5 volts is found, continue with Step 4 . B. If no voltage is found, continue with Step 3 . 3. Disconnect connector X032 , and use a multimeter to test for voltage on connector X032 pin 5. There should be 5 volts present. A. If 5 volts is found, there is an open circuit in the header (HH) harness between connector X305 and connector X032 wire 848 pink.

Locate the open and repair. B. If no voltage is found, continue with Step 3 . 4. Disconnect connector X007 , and use a multimeter to test for voltage on connector X007 pin 22. There should be 5 volts present. A. If 5 volts is found, there is an open circuit in the feeder (FE) harness between connector X032 pin 5 and connector X007 pin 22 wire 848 pink or 757 pink. Locate the open and repair. B. If no voltage is found, there is an open circuit in the front frame (FF) harness between connector X007 pin 22 and connector X020 pin J3-26 wire 757 pink or 726 pink. Locate the open and repair. 5. Disconnect connector X305 and connector X032 .

Use a multimeter to check for continuity between connector X305 pin 2 and connector X032 pin 1. A. If continuity is found, continue with Step 7 . B. If no continuity is found, there is an open circuit in the header (HH) harness between connector X305 pin 2 and connector X032 pin 1 wire 738 yellow. Locate the open and repair. 9706 1 27/05/2004 G.10.A / 45