CROP PROCESSING - FEEDING Header feeding Sensing system Header type module - Short circuit to B+ (K.25.D.95.80 - G.30.B.54) AFX8010 E0148-03 - Header Type Module Context: Headers used on the AFX combine may be equipped with a header type module, which is used to identify the header type to the combine. This allows the operator to store configuration information in memory that may be recalled when the header is attached. Cause: The header type module (R-20) circuit is shorted to a higher than normal voltage source. Possible failure modes: 1. Sensor supply or signal wiring shorted to 12 volts . 2. Sensor ground wiring is open. 3. Controller internal failure (internal regulator failure).
Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "HDR HEIGHT/TILT" or "HEADER" sort menu, and select "TYPE SEN" to check the voltage range. The normal operating range for the header type module circuit is 0.3 - 4.72 volts . The normal voltage readings for the different header types are as follows: A. If the voltage reading is 4.72 volts or greater, continue with Step 2 . B. If the voltage reading is within the proper limits, the shorted wire may not be powered up at this time. Continue the troubleshooting at Step 5 . 2. Disconnect the header type module connector X435. Locate the wire 1223 pink in the connector using the following table:
Use a multimeter to check the voltage between connector X435 wire 1223 pink and chassis ground. There should be 5 volts . 9711 1 27/05/2004 K.25.D / 15 Header Type Sensor Voltage Corn header 3.72 - 4.72 volts Grain header 2.93 - 3.72 volts Draper header 2.02 - 2.93 volts Pick up header 1.22 - 2.02 volts Programmable header 0.3 - 1.22 volts No header installed 0 - 0.3 volts Header Type Connector X435 5 volts Power Wire Corn header Pin A Grain header Pin A Draper header Pin A Pick up header Pin F Programmable header Pin F