CROP PROCESSING - THRESHING Axial flow threshing Control valve Speed control valve - Short circuit to B+ (K.40.C.14.10 - G.30.B.54) AFX8010 E0304-03 - Rotor CVT Pump Current Sense Context: The Rotor CVT Pump Current Sense circuit is the ground path for the Rotor Pump Swash Minus (L-41) and/or Rotor Pump Swash Plus (L-40) PWM solenoids. By monitoring current flow on the return path of the solenoids, the module can provide precise control of solenoid engagement. When this error message is reported, this is an indication of excessive current draw on the circuit, or a result of a high voltage short on the return line. Cause:
The Rotor Pump Swash Minus (L-41) and/or Rotor Pump Swash Plus (L-40) circuits have excessive current draw, or are shorted to a high voltage source. Possible failure modes: 1. Bad solenoid. 2. Return side wiring shorted to 12 volts . 3. Controller internal failure (internal regulator failure). Solution: 1. Key switch ON, combine engine running. Enter the Universal Display Plus "DIAG" screen. Select the "THRESHING" or "ROTOR" sort menu, and select "CVT PMP VLV" to check the current. Engage the separator switch S-30, and use the rotor speed switch S-17 to increase and decrease rotor speed while monitoring the current.
The proper current for both rotor pump solenoids should be approximately 1.0 - 1.5 amps . The fault code is triggered by current flow greater than 3.3 amps . A. If the reading is greater than 3.3 amps on either circuit, continue with Step 3 . B. If the readings are normal ( 1.0 - 1.5 amps ), continue the troubleshooting at Step 8 . C. If there is no current reading on either circuit, the module may have failed as a result of a 12V short on the Isense circuit. Continue with Step 6 . NOTE: If the current reading is high, immediately shut off the circuit after verifying the reading to prevent module damage. 2.
Turn the key switch to the OFF position and disconnect the rotor pump swash solenoid connector X408 . Use a multimeter to check the resistance of the rotor pump swash plus solenoid between connector X408 pins A & B. Repeat this resistance check for the rotor pump swash minus solenoid between connector X408 pins C & D. The proper resistance range for the solenoids is 16k - 20k ohms . A. If either solenoid is out of specification, replace the solenoid. Continue with Step 8 . B. If both solenoids are within specification, continue with Step 5 . 3. Disconnect connector X011 .
Use a multimeter to check the resistance of the rotor pump swash plus solenoid circuit between connector X011 pins 28 & 2. Repeat this resistance check for the rotor pump swash minus solenoid between connector X011 pins 28 & 1. A. If the resistance is lower than the previously measured resistance, there is a short in the gearbox (GB) harness between connector X022 and connector X011 wires 1046 white (swash plus) or 1047 white (swash minus) and 1066 blue, 1067 blue or 1065 blue. Locate the short and repair. Continue with Step 8 . B. If the resistance is the same as previously measured, continue with Step 8 . 9714 1 27/05/2004 K.40.C / 67