CROP PROCESSING - THRESHING Axial flow threshing 4. Disconnect connector X034A . Use a multimeter to check the resistance of the rotor pump swash plus solenoid circuit between connector X034A pins 1 & 4. Repeat this resistance check for the rotor pump swash minus solenoid between connector X034A pins 1 & 3. A. If the resistance is lower than the previously measured resistance, there is a short in the main frame (MF) harness between connector X034A and connector X011 wires 1046 white (swash plus) or 1047 white (swash minus) and 1066 blue, 1067 blue or 1065 blue. Locate the short and repair. Continue with Step 8 . B. If the resistance is the same as previously measured, continue with Step 5 .
5. Carefully disconnect connectors X013 and X014 on the bottom of CCM3 module. Use a multimeter to check the resistance of the rotor pump swash plus solenoid circuit between connector X013 pin J2-10 and connector X014 pin J3-31. Repeat this resistance check for the rotor pump swash minus solenoid between connector X013 pin J2-10 and connector X014 pin J3-21. A. If the resistance is lower than the previously measured resistance, there is a short in the expansion (EX) harness between connector X014 , connector X034A and connector X013 wires 1046 white (swash plus) or 1047 white (swash minus) and 1066 blue, 1067 blue or 1065 blue. Locate the short and repair. Continue with Step 8 . B.
If the resistance is the same as previously measured, continue with Step 6 . 6. Key on. Disconnect connector X408 . Use a multimeter to check for voltage at connector X408 pin B or D (harness end). There should be no voltage on either wire. A. If there is no voltage present on the wires, continue with Step 8 . B. If there is voltage on the wire, continue with Step 8 . NOTE: The high voltage source may not be present as it may not be currently powered up. If the fault code typically appears when operating another circuit, activate that circuit while performing this check. 7. Key on. Disconnect connector X011 .
Use a multimeter to check for voltage at the main frame (MF) harness end of connector X011 pin 28. There should be no voltage. A. If there is voltage present, continue with Step 8 . B. If there is no voltage on the wire, the short to voltage is in the gearbox (GB) harness between connector X408 and connector X011 wires 1066 blue, 1067 blue or 1065 blue. Locate the short and repair. Continue with Step 8 . NOTE: The high voltage source may not be present as it may not be currently powered up. If the fault code typically appears when operating another circuit, activate that circuit while performing this check. 8. Key on. Disconnect connector X034A .
Use a multimeter to check for voltage at the expansion (EX) harness end of connector X034A pin 1. There should be no voltage. A. If there is no voltage present, there is a short to voltage in the main frame (MF) harness between connector X011 and connector X034A wire 1065 blue. Locate the short and repair. Continue with Step 8 . B. If there is voltage on the wire, the short to voltage is in the expansion (EX) harness between connector X034A and connector X013 pin J2-10 wire 1065 blue. Locate the short and repair. Continue with Step 8 . NOTE: The high voltage source may not be present as it may not be currently powered up.
If the fault code typically appears when operating another circuit, activate that circuit while performing this check. 9. The sense resistor in the module for the Rotor Pump CVT Current Sense circuit is easily damaged as a result of excessive current draw or a short to high voltage. After locating the source of the problem and correcting, the module must be checked for damage. Carefully disconnect connector X013 from the bottom of the CCM3 module. Use a multimeter to check resistance between connector X013 pin J2-10 on the module and chassis ground. There should be less than 1 ohms resistance. A. If there is infinite resistance, the sense resistor in the CCM3 module has failed.
Replace the module. B. If the resistance is correct, the sense resistor in the CCM3 module is okay, and the circuit should function correctly. Continue with Step 9 . 9714 1 27/05/2004 K.40.C / 68