Case IH AFX8010 — THRESHING Axial flow threshing

CROP PROCESSING - THRESHING Axial flow threshing Control valve Speed control valve - Unidentified failure (K.40.C.14.10 - G.30.B.46) AFX8010 E0330-11 - Rotor CVT Pump Valve Cause: The Rotor Pump Swash Minus (L-41) and/or Rotor Pump Swash Plus (L-40) circuits are shorted to ground. Possible failure modes: 1. Supply wiring damaged. 2. Solenoid failed. 3. Controller internal failure (internal regulator failure). Solution: 1. Key switch ON, combine engine running. Enter the Universal Display Plus "DIAG" screen. Select the "THRESHING" or "ROTOR" sort menu, and select "CVT PMP VLV" to check the current.

Engage the separator switch S-30, and use the rotor speed switch S-17 to increase and decrease rotor speed while monitoring the current. The current should vary gradually between 0 - 90 mA ( 0 - 4.4 volts ), depending on rotor speed. If the current spikes to a maximum of 100 mA (> 4.7 volts ), and then abruptly drops to zero, there is a short to ground on the output lead to the control valve. A. If the current spikes to maximum , and then abruptly drops to zero, continue with step 2 . 2. Turn the key switch to the "OFF" position. Disconnect the rotor pump swash solenoids connector X408 .

Use a multimeter to check the resistance of the rotor pump swash solenoid coils between terminals D & C, and then between terminals A & B. The proper resistance range for the solenoid coils is 16k - 20k ohms . B. If the voltage readings are within the proper ranges, continue with step 10 . A. If either of the solenoid coils is out of specification, replace the solenoid. B. If the solenoid coils are within specifications, continue with step 3 . 3. Use a multimeter to check for continuity between the rotor pump swash minus solenoid coil terminals D or C and chassis ground. There should not be continuity to ground. A. If there is continuity to ground, replace the solenoid. B.

If there is no continuity to ground, continue with step 4 . 4. Use a multimeter to check for continuity between the harness end of connector X408 pin C and chassis ground. There should not be continuity to ground. A. If there is continuity to ground, continue with step 5 . B. If there is no continuity to ground, continue with step 7 . 5. Disconnect connector X011 . Use a multimeter to check for continuity between the main frame (MF) harness end of connector X011 pin 1 and chassis ground. There should not be continuity to ground. A.

If there is no continuity to ground, there is a short to ground in the gearbox (GB) harness between connector X011 and connector X402 wire 1047 white.Locate the short and repair. B. If there is continuity to ground, continue with step 6 . 6. Disconnect connector X034A . Use a multimeter to check for continuity between the front frame (FF) harness end of connector X034A pin 3 and chassis ground. There should not be continuity to ground. 9714 1 27/05/2004 K.40.C / 71