CROP PROCESSING - THRESHING Axial flow threshing A. If there is no continuity to ground, there is a short to ground in the main frame (MF) harness between connector X011 and connector X034A wire 1047 white. Locate the short and repair. B. If there is continuity to ground, there is a short to ground in the expansion (EX) harness between connector X034A and connector X014 pin J3-21 wire 1047 white. Locate the short and repair. 7. Use a multimeter to check for continuity between the harness end of connector X408 pin A and chassis ground. There should not be continuity to ground. A. If there is continuity to ground, continue with step 8 . B.
If there is no continuity to ground, continue with step 10 . 8. Disconnect connector X011 . Use a multimeter to check for continuity between the main frame (MF) harness end of connector X011 pin 2 and chassis ground. There should not be continuity to ground. A. If there is no continuity to ground, there is a short to ground in the gearbox (GB) harness between connector X011 and connector X402 wire 1046 white.Locate the short and repair. B. If there is continuity to ground, continue with step 9 . 9. Disconnect connector X034A . Use a multimeter to check for continuity between the front frame (FF) harness end of connector X034A pin 4 and chassis ground.
There should not be continuity to ground. A. If there is no continuity to ground, there is a short to ground in the main frame (MF) harness between connector X011 and connector X034A wire 1046 white. Locate the short and repair. B. If there is continuity to ground, there is a short to ground in the expansion (EX) harness between connector X034A and connector X014 pin J3-31 wire 1046 white. Locate the short and repair. 10. Visually inspect the harness and connectors for damage, bent or dislocated, corroded terminals, or broken wires. A. If no damage is found, erase the fault code and continue operation. 9714 1 27/05/2004 K.40.C / 72