CROP PROCESSING - THRESHING Axial flow threshing A. If the resistance is lower than the previously measured resistance, there is a short in the harness between connector X034A and connector X011 wires 1048 white and 1062 blue. Locate the short and repair. Continue with Step 7 . 5. Carefully disconnect connector X013 on the bottom of CCM3 module. Use a multimeter to check the resistance of the Rotor ETR clutch solenoid circuit between connector X013 pins J2-30 & J2-40. B. If the resistance is the same as previously measured, continue with Step 4 . A.
If the resistance is lower than the previously measured resistance, there is a short in the harness between connector X034A and connector X013 wires 1048 white and 1062 blue. Locate the short and repair. Continue with Step 7 . B. If the resistance is the same as previously measured, reattach all connectors and continue with Step 5 . 6. Key on. Disconnect connector X410 . Use a multimeter to check for voltage at connector X410 pin B (harness end). There should be no voltage on this wire. A. If there is no voltage present on the wire, continue with Step 7 . B. If there is voltage present on the wire, continue with Step 6 . NOTE:
The high voltage source may not be present as it may not be currently powered up. If the fault code typically appears when operating another circuit, activate that circuit while performing this check. 7. Key on. Disconnect connector X011 . Use a multimeter to check for voltage at connector X011 pin 26 (module side of connector). There should be no voltage on this wire. A. If there is no voltage on the wire, the short to voltage is between connector X410 and connector X011 wire 1062 blue. Locate the short and repair. Continue with Step 7 . B. If there is voltage on the wire, continue with Step 8 . NOTE: The high voltage source may not be present as it may not be currently powered up.
If the fault code typically appears when operating another circuit, activate that circuit while performing this check. 8. Key on. Disconnect connector X034A . Use a multimeter to check for voltage at connector X034A pin 8 (module side of connector). There should be no voltage on this wire. A. If there is no voltage on the wire, the short to voltage is between connector X034A and connector X011 wire 1062 blue. Locate the short and repair. Continue with Step 7 . B. If there is voltage on the wire, the short to voltage is between connector X034A and connector X013 pin J2-40 wire 1062 blue. Locate the short and repair. Continue with Step 7 . NOTE:
The high voltage source may not be present as it may not be currently powered up. If the fault code typically appears when operating another circuit, activate that circuit while performing this check. 9. The sense resistor in the module for the Rotor ETR Clutch Current Sense circuit is easily damaged as a result of excessive current draw or a short to high voltage. After locating the source of the problem and correcting, the module must be checked for damage. Disconnect connector X034A . Use a multimeter to check resistance between connector X034A pin 8 and chassis ground. There should be less than 1 ohms resistance. A.
If there is infinite resistance, the sense resistor in the CCM3 module has failed. Replace the module. B. If the resistance is correct, the sense resistor in the CCM3 module is okay, and the circuit should function correctly. Continue with Step 8 . 10. Operate the combine while monitoring the Rotor ETR Clutch Current Sense circuit current on the Universal Display Plus "DIAG" screen. A. If no high out of range current readings are seen, erase the error code and continue operation. 9714 1 27/05/2004 K.40.C / 76