Case IH AFX8010 — THRESHING Axial flow threshing

CROP PROCESSING - THRESHING Axial flow threshing Control valve Clutch control valve - Unidentified failure (K.40.C.14.20 - G.30.B.46) AFX8010 E0308-11 - Rotor ETR Clutch Valve Cause: The Rotor ETR Clutch Valve (L-45) circuit is open, or shorted to ground. Possible failure modes: 1. Supply wiring damaged. 2. Bad solenoid. 3. Controller internal failure (internal regulator failure). Solution: 1. Start the combine engine. Enter the Universal Display Plus "DIAG" screen. Select the "THRESHING" or "ROTOR" sort menu, and select "ETR CTCH VLV" to monitor the current flow. Use the "COMMAND" and "ENGAGE" functions to power the circuit at 100% output.

The proper current is approximately 1.0 - 1.5 amps . A. If the current reading goes to maximum, and then back to zero, the circuit is shorted to ground and the software has shut off the output to protect the module and wiring. Continue with Step 2 . B. If the reading is 0 amps , the circuit is open. Continue with Step 5 . 2. Disconnect the Rotor ETR clutch connector X410 . Use a multimeter to check between connector X410 pin A (valve side) and chassis ground. C. If the reading is within the proper range, the circuit is working properly. Continue with Step 11 . A. If there is continuity, the Rotor ETR clutch solenoid is shorted to ground. Replace the solenoid. B.

If there is no continuity, continue with Step 3 . 3. Use a multimeter to check for continuity between connector X410 pin A (harness side) and chassis ground. Flex the gearbox (GB) harness between the clutch valve and connector X011 while making this check. A. If there is continuity to ground, continue with Step 4 . B. If there is no continuity to ground, continue with step 9 . 4. Disconnect connector X011 . Use a multimeter to check for continuity between connector X011 pin 4 and chassis ground. Flex the main frame (MF) harness between the connector X011 and connector X013 while making this check. A.

If there is no continuity to ground, the short to ground is in the gearbox (GB) harness between connector X011 and connector X410 wire 1048 white. Locate the short and repair. B. If there is continuity to ground, continue with step 6 . 5. Disconnect connector X034A . Use a multimeter to check for continuity between connector X034A pin 5 and chassis ground. Flex the main frame (MF) harness between the connector X011 and connector X013 while making this check. A. If there is no continuity to ground, the short to ground is in the main frame (MF) harness between connector X011 and connector X034A wire 1048 white. Locate the short and repair. B.

If there is continuity to ground, the short to ground is in the expansion (EX) harness between connector X034A and connector X013 pin J2-30 wire 1048 white. Locate the short and repair. 9714 1 27/05/2004 K.40.C / 79