CROP PROCESSING - THRESHING Axial flow threshing Control valve Clutch control valve - Unidentified failure (K.40.C.14.20 - G.30.B.46) AFX8010 E0315-11 - Rotor RTF Clutch Valve Cause: The rotor RTF clutch valve (L-46) circuit open or is shorted to ground. Possible failure modes: 1. Supply wiring shorted to ground or open circuit. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "THRESHING" or "ROTOR" sort menu, and select "RTF CTCH VLV". Change the drop-down list to "STATUS", and press the "OFF" button to change the circuit output to "ON".
The "STATUS" screen should indicate "OK" if the circuit is working properly. A. If the status screen indicates "ERROR", the circuit is open or shorted to ground. Continue with Step 2 . B. If the status screen indicates "OK", the circuit is working properly. Continue with Step 7 . 2. Turn the key switch to the OFF position and disconnect the rotor RTF clutch connector X409 . Use a multimeter to check the resistance of the rotor RTF clutch solenoid. The proper resistance range for the coil is 1.0 - 8.0 ohms . A. If out of specification, replace coil. B. If the coil is within specification, continue with Step 3 . 3.
Use a multimeter to check for continuity between the gearbox (GB) harness end of connector X409 pin 1 and chassis ground. Flex the gearbox (GB) harness while making this check. A. If no continuity to ground is found, continue with Step 4 . B. If there is continuity to ground, continue with Step 6 . 4. Turn the key switch to the ON position. Use the Universal Display Plus "DIAG" screen controls to manually power the rotor RTF clutch solenoid. Use a multimeter to check for 12 volts between connector X409 pin 1 and chassis ground. A. If 12 volts is not present, continue with Step 5 . B. If 12 volts is found, continue with Step 7 . 5. Key switch to the ON position.
Use the Universal Display Plus "DIAG" screen controls to manually power the rotor RTF clutch solenoid. Use a multimeter to check for 12 volts between connector X011 pin 27 and chassis ground. A. If 12 volts is not present, continue with step 8 . B. If 12 volts is read, there is an open circuit in the gearbox (GB) harness between connector X011 and connector X409 wire 1049 white. Locate the open and repair. 6. Key switch to the ON position. Use the Universal Display Plus "DIAG" screen controls to manually power the rotor RTF clutch solenoid. Use a multimeter to check for 12 volts between connector X034A pin 9 and chassis ground. A.
If 12 volts is not present, there is an open circuit in the expansion (EX) harness between connector X034A and connector X020 J3-3 wire 1049 white. Locate the open and repair. 9714 1 27/05/2004 K.40.C / 84