Case IH AFX8010 — THRESHING Axial flow threshing

CROP PROCESSING - THRESHING Axial flow threshing Electrical motor - Short circuit (K.40.C.82 - G.30.B.52) AFX8010 E0044-06 - Concave Current Sense Cause: The concave clearance motor (M-04) circuit indicates high current draw. Possible failure modes: 1. Circuit connection shorted. 2. Excessive mechanical load on motor. 3. Controller internal failure (internal regulator failure). Solution: 1. This is an H-bridge controlled circuit, which reverses the power and ground connections to the concave clearance motor M-04 and grain tank covers motor M-12 in order to move them in either direction. A relay is used to switch operation between the two motors.

The CCM module monitors both sides of the circuit during operation, and issues one or several fault codes, depending on the failure type detected. Use the following procedure to determine the location of the fault. A. If the concave motor operates in one direction only, and the fault code E0044-06 - Concave Current Sense is displayed, continue with step 2 . B. If the concave motor operates in one direction only, and both fault codes E0044-06 - Concave Current Sense and E0078-11 - Concave Motor are displayed, continue with step 3 . C. If the concave motor and grain tank covers motor operate in one direction only, and the following fault codes are displayed:

E0044-06 - Concave Current Sense E0045-06 - Covers Current Sense E0078-11 - Concave Motor E0079-11 - Grain Tank Covers Motor continue with step 6 . 9714 1 27/05/2004 K.40.C / 88 Step Description 1 Enter the Universal Display Plus "ERROR" screen. Record the error list, and then select "CLEAR". Clear all errors from the CCM1 module. 2 Enter the Universal Display Plus "DIAG" screen. Select the "THRESHING" sort menu, and select "CONCAVE MTR". Start the combine, and use the "COMMAND" and "ENGAGE" functions to manually raise and lower the concaves. Record in which directions the concave motor operates.

3 Select the "GRAIN HANDLING" sort menu, and select "COVERS MTR" (if combine is equipped with grain tank covers). Use the "COMMAND" and "ENGAGE" functions to manually raise and lower the grain tank covers. Record in which directions the covers motor operates. 4 Enter the Universal Display Plus "ERROR" screen, and depress the "REFRESH" button to update the error history. Check for the following fault codes: E0044-06 - Concave Current Sense E0045-06 - Covers Current Sense E0078-11 - Concave Motor E0079-11 - Grain Tank Covers Motor . 5 Use the appropriate result below to determine the location of the fault.