CROP PROCESSING - THRESHING Axial flow threshing D. If the concave motor does not operate in either direction, and the fault code E0078-11 - Concave Motor is displayed, continue with step 9 . E. If the concave motor does not operate in either direction, and both fault codes E0044-06 - Concave Current Sense and E0078-11 - Concave Motor are displayed, continue with step 14 . F. If the grain tank covers motor operates in one direction only, and the fault code E0045-06 - Covers Current Sense is displayed, continue with step 15 . G.
If the grain tank covers motor operates in one direction only, and both fault codes E0045-06 - Covers Current Sense and E0079-11 - Grain Tank Covers Motor are displayed, continue with step 16 . H. If the grain tank covers motor does not operate in either direction, and the fault code E0045-06 - Covers Current Sense is displayed, continue with step 20 . I. If the grain tank covers motor does not operate in either direction, and both fault codes E0045-06 - Covers Current Sense and E0079-11 - Grain Tank Covers Motor are displayed, continue with step 31 . J.
If both the concave motor and grain tank covers motor do not operate in either direction, and the fault codes E0078-11 - Concave Motor and E0079-11 - Grain Tank Covers Motor are displayed, continue with step 32 . K. If both the concave motor and grain tank covers motor do not operate in either direction, and there are no fault codes displayed, continue with step 34 . 2. Manually operate the concave motor using the "DIAG" screen controls, while having an observer inspect the concave linkage movement for binding. A. The concave clearance adjustment motor is bound up. See the appropriate repair manual chapter for repair. 3. The concave clearance motor operates in one direction only.
Fault codes indicate a short to ground. Disconnect the concave clearance motor connector X190 . Measure the resistance on concave motor connector X190 between pin 1 and pin 2. The proper resistance range for the motor is 1.0 - 5.0 ohms . A. If out of specification, replace concave motor. B. If the motor coil resistance is within specification, continue with Step 4 . 4. Use a multimeter to check for continuity on the harness end of connector X190 pin 2 and chassis ground. Flex the concave extension (CC) harness while making this check. There should not be any continuity to ground. A. If there is no continuity to ground, erase the fault code and continue operation. B.
If there is continuity to ground, continue with Step 6 . 5. Disconnect connector X456 . Use a multimeter to check for continuity between the main frame (MF) harness end of connector X456 pin 2 and chassis ground. There should not be any continuity. A. If there is no continuity to ground, there is a short to ground in the concave extension (CC) harness between connector X456 and connector X190 wire 695 white. Locate the short and repair. 9714 1 27/05/2004 K.40.C / 89