Case IH AFX8010 — THRESHING Axial flow threshing

CROP PROCESSING - THRESHING Axial flow threshing Sensing system Concave position sensor - Short circuit to B+ (K.40.C.95.82 - G.30.B.54) AFX8010 E0034-03 - Concave Position Sensor Cause: The concave position sensor (R-06) circuit is shorted to high voltage, or the sensor ground is open. Possible failure modes: 1. Sensor supply or signal wiring is shorted to high voltage (12V). 2. Sensor ground wiring is open. 3. Module internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "THRESHING" sort menu, and select "CONCAVE POS SEN" to check the voltage range.

Raise and lower the concaves several times while monitoring the voltage; the voltage should stay within range, and should change smoothly with concave movement. The proper voltage range is 0.3 - 5.2 volts . A. If the voltage reading is high (> 5.2 volts ) out of range, continue with Step 2 . B. If the voltage reading is within the proper limits, the circuit may not be shorted at this time. Continue the troubleshooting at Step 7 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires.

Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Key off. Disconnect connector X189 , and use a multimeter to test for continuity to ground on connector X189 pin 3. There should be low resistance ( 1 ohms ) to ground. A. If continuity is found ( 1 ohms ), continue with Step 5 . B. If no continuity is found, or there is high resistance (> 1 ohms ) to ground, continue with Step 3 . 3. Key off. Disconnect connector X456 . Use a multimeter to test for continuity between connector X189 pin 3 and connector X456 pin 4. A. If continuity is found, continue with Step 4 . B.

If no continuity is found, there is an open circuit in the concave (CC) harness between connector X189 pin 3 and connector X456 pin 4 wire 456 blue. Locate the open and repair. 4. Key off. Carefully remove connector X019 from the bottom of CCM1. Use a multimeter to test for continuity between connector X456 pin 4 and connector X019 pin J2-14. A. If continuity is found, continue with Step 4 . B. If no continuity is found, there is an open circuit in the main frame (MF) harness between connector X456 pin 4 and connector X019 pin J2-14 wire 456 blue or 460 blue. Locate the open and repair. 5. Key off.

Use a multimeter to test for continuity between connector X019 pin J2-14 on CCM1 and chassis ground. There should be low resistance ( 1 ohms ) to ground. A. If no continuity is found, or there is high resistance (> 1 ohms ) to ground, the CCM1 module is not supplying a ground path for the sensor due to an internal failure. Replace the CCM1 module. B. If continuity is found, the ground path for the sensor tests okay. Reconnect all connectors and retest for continuity to ground at Step 2 . 9714 1 27/05/2004 K.40.C / 107