CROP PROCESSING - THRESHING Axial flow threshing 6. Disconnect connector X189 , and use a multimeter to test for voltage on connector X189 pin 2. There should not be any voltage present. A. If no voltage is found, continue with Step 6 . B. If high (> 5.2 volts ) voltage is found, continue with step 8 . 7. Disconnect connector X456 , and use a multimeter to test for voltage on connector X456 pin 5. There should not be any voltage present. A. If no voltage is found, there is a short to high voltage in the concave (CC) harness between connector X456 and connector X189 wire 411 yellow. Locate the short and repair. B.
If high (> 5.2 volts ) voltage is found, there is a short to high voltage in the main frame (MF) harness between connector X456 pin 5 and connector X019 pin J2-19 wire 411 yellow. Locate the short and repair. 8. Disconnect connector X189 , and use a multimeter to test for voltage on connector X189 pin 1. There should be 5 volts present. A. If 5 volts is found, continue with Step 7 . B. If high (> 5.2 volts ) voltage is found, continue with step 8 . NOTE:
This supply circuit is also used to supply power to the lateral inclination sensor B02,header lift pressure sensor B-29, feeder angle R-03, and PTO box lube pressure sensor B-60, so a short to 12 volts anywhere on the supply circuit will activate this error code. 9. Disconnect connector X456 , and use a multimeter to test for voltage on connector X456 pin 3. There should be 5 volts present. A. If 5 volts is found, there is a short to high voltage in the concave (CC) harness between connector X456 and connector X189 wire 489 pink. Locate the short and repair. B.
If high (> 5.2 volts ) voltage is found, there is a short to high voltage in the main frame (MF) harness between connector X456 pin 3, connector X170 pin A (B-02), connector X174 pin 3 (R-03), connector X279 pin B (B-29), connector X399 pin B (B-60) and connector X019 pin J2-31 on one of the following wires: - wire 498 pink, connector X456 pin 3 to MF harness splice - wire 451 pink, connector X170 pin A to MF harness splice - wire 751 pink, connector X174 pin 3 to MF harness splice - wire 728 pink, connector X279 pin B to MF harness splice - wire 1286 pink, connector X399 pin B to MF harness splice - wire 453 pink, MF harness splice to connector X019 pin J2-31. Locate the short and repair.
10. Operate the machine while monitoring the Universal Display Plus "DIAG" screen. A. If no high out of range readings are indicated, erase the fault code and continue operation. B. If the fault code immediately resets, determine which 12 volts circuit (such as the concave clearance motor) was activated to cause the short. 9714 1 27/05/2004 K.40.C / 108