CROP PROCESSING - THRESHING Axial flow threshing Sensing system Concave position sensor - Open circuit (K.40.C.95.82 - G.30.B.50) AFX8010 E0034-05 - Concave Position Sensor Cause: The concave position sensor (R-06) circuit is open or shorted to ground. Possible failure modes: 1. Sensor signal wiring is open or shorted to ground. 2. Loss of power to the sensor. 3. Module internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "THRESHING" sort menu, and select "CONCAVE POS SEN" to check the voltage range.
Raise and lower the concaves several times while monitoring the voltage; the voltage should stay within range, and should change smoothly with concave movement. The proper voltage range is 0.3 - 5.2 volts . A. If the voltage reading is low ( 0.3 volts ) out of range, continue with Step 2 . B. If the voltage reading is within the proper limits, the circuit may not be open or shorted to ground at this time. Continue the troubleshooting at Step 5 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires.
Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect connector X189 , and use a multimeter to test for voltage on connector X189 pin 1. There should be 5 volts present. A. If 5 volts is found, continue with Step 3 . B. If no voltage is found, continue with step 3 . 3. Disconnect connector X456 , and use a multimeter to test for voltage on connector X456 pin 3. There should be 5 volts present. A. If 5 volts is found, there is an open circuit in the concave (CC) harness between connector X456 and connector X189 wire 489 pink. Locate the open and repair. B.
If no voltage is found, there is an open circuit in the main frame (MF) harness between connector X456 pin 3 and connector X019 pin J2-31 wire 498 pink or 453 pink. Locate the open and repair. 4. Disconnect connector X189 . Use a multimeter to check for continuity between connector X189 pin 2 and ground. A. If no continuity is found, continue with Step 4 . B. If continuity is found, continue with step 4 . 5. Disconnect connector X456 . Use a multimeter to check for continuity between connector X456 pin 5 and ground. A. If no continuity is found, there is a short to ground in the concave (CC) harness between connector X456 and connector X189 wire 411 yellow. Locate the open and repair. B.
If continuity is found, there is a short to ground in the front frame (FF) harness between connector X456 pin 5 and connector X019 pin J2-19 wire 411 yellow. Locate the short and repair. 9714 1 27/05/2004 K.40.C / 115