CROP PROCESSING - STORING AND HANDLING Grain storing Sensing system Level sensor - Short circuit to B+ (K.60.B.95.80 - G.30.B.54) AFX8010 E0159-03 - Grain Tank Full Sensor Cause: The grain bin switch (S-28 & S-29) circuit is shorted to high voltage, or the ground path is open. Possible failure modes: 1. Switch supply or ground wiring shorted to 12 volts . 2. Open circuit on switch ground path. 3. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "GRAIN HANDLING" sort menu, and select "TANK FULL SEN" to check the voltage range. The normal voltage range is 0 - 4.9 volts .

The proper voltage range with both switches neutral (tank empty) is approximately 2.5 volts . The proper voltage range with the grain bin 3/4 full switch S-28 depressed is approximately 3.3 volts . The proper voltage range with both grain bin switches depressed is approximately 3.7 volts . A. If the voltage reading is high (> 4.9 volts ) out of range, continue with step 2 . B. If the voltage reading is within the proper limits, continue the troubleshooting with step 10 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connectors are fully installed. Inspect the terminals and wires in each connector for pushed back or corroded terminals or damaged wires.

Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Disconnect the grain bin full switch S-29 connector X109 . A. If the voltage drops to 0 - 4.9 volts , the short is in the reference ground wire for the circuit. Continue with step 3 . 3. Disconnect the main frame (MF) harness from the grain tank (GT) harness at connector X009 . Use a multimeter to check for voltage on the main frame (MF) harness end of connector X009 pin H. B. If the voltage remains high (> 4.9 volts ) out of range, continue with step 4 . A.

If there is no voltage present, there is a short in the grain tank (GT) harness between connector X009 pin H and connector X109 pin A wire 443 blue. Locate the short and repair. B. If there is voltage present, there is a short in the main frame (MF) harness between connector X009 pin H and connector X016 pin J2-14 wire 443 blue or wire 465 blue. Locate the short and repair. 4. Disconnect the grain bin full switch S-29 connector X109 . Use a multimeter to check for continuity between connector X109 pin A and chassis ground. There should be continuity. A. If continuity is found, continue with step 6 . B. If no continuity is found, continue with step 5 . 5.

Disconnect the main frame (MF) harness from the grain tank (GT) harness at connector X009 . Use a multimeter to check for continuity between the main frame (MF) harness end of connector X009 pin H and chassis ground. There should be continuity. A. If there is continuity, there is an open circuit in the grain tank (GT) harness between connector X009 pin H and connector X109 pin A wire 443 blue. Locate the open and repair. B. If there is no continuity, there is an open circuit in the main frame (MF) harness between connector X009 pin H and connector X016 pin J2-14 wire 443 blue or wire 465 blue. Locate the open and repair. 9716 1 27/05/2004 K.60.B / 62