Case IH AFX8010 — STORING AND HANDLING Grain storing

CROP PROCESSING - STORING AND HANDLING Grain storing is located in the center of the front grain bin extension. Both switches may be adjusted up or down on their mounting brackets to ensure that they are triggered by the material being harvested before the grain bin overflows. The two switches are connected in series through the grain tank (GT) harness, and an input is provided from the grain bin 3/4 full switch S-28 to the CCM2 module at connector X016 pin J2-22. The CCM2 module monitors the change in resistance that occurs as the grain bin switches are closed by the increasing level of material in the grain bin.

In the event that a fault occurs with one of the switches or the wiring to the switches, a fault code will be displayed to the operator. E0159-03 - Grain Tank Full Sensor E0159-05 - Grain Tank Full Sensor When the threshing system is engaged, and the grain bin 3/4 full switch S-28 is closed, the "Bin Full" light will illuminate on the shaft speed monitor, and the rotating beacons (if equipped) will flash to alert a grain truck operator to prepare for unloading the grain bin, and will continue to flash until the grain bin is emptied. NOTE:

If the work lights are activated, the rotating beacons will only flash for approximately 10 seconds when the grain bin 3/4 full switch is closed, and will flash again for approximately 10 seconds when the grain bin full switch is closed. When the material level closes the grain bin full switch S-29, the "Bin Full" light on the shaft speed monitor will flash, and a buzzer will sound. The alarm message "A0030 Grainbin FULL" will also be displayed to the operator. 9716 1 27/05/2004 K.60.B / 64