CROP PROCESSING - CLEANING Primary cleaning 13. Using a press, remove the steel cased rubber bushing (1) from the rocker arm pivot pin (2) . Press the rocker arm mounting flange (3) from the bushing. ATTENTION: Lower Connecting Arm Bushings 14. Inspect the journal (1) for wear or damage. The diameter of the journal is to be 28.064 - 28.085 mm ( 1.105 - 1.106 in ). Journals with diameters less than that specified should be replaced. The rubber bushings are more likely to wear or crack. Inspect the rubber bushings and replace if worn or cracked. 40015721g 11 40015722 12 15. Repeat the earlier steps of removing the upper sieves and their components Upper sieve - Remove (K.62.B.57 - F.10.A.10) .
16. Place blocks and jacks under the shoe to support it. Use caution when proceeding with these steps as the components are heavy and unstable. 17. Carefully turn out the five cap screws at (1) and (2) . NOTE: Additional items may be removed to better illustrate this step. 50015725x 13 9717 1 27/05/2004 K.62.B / 12