Case IH AFX8010 — CLEANING Primary cleaning

CROP PROCESSING - CLEANING Primary cleaning 18. Turn out two cap screws (1) . Remove the lower connecting arm bushing cap (2) and mounting plate (3) from the right side of the combine. Repeat this step for the left side of the combine 10036376 14 19. Bushings are inside the access hole on the left hand side of the machine. 10036373 15 20. Using a press, remove the steel cased rubber bushing (1) from the mounting plate journal (2) . NOTE: Inspect the journal (1) for wear or damage. The diameter of the journal is to be 28.064 - 28.085 mm ( 1.105 - 1.106 in ) . Journals with diameters less than that specified should be replaced. 40015729x 16 9717 1 27/05/2004 K.62.B / 13