CROP PROCESSING - CLEANING Primary cleaning 8. Turn out the appropriate cap screw (1) several turns. Apply blows using a mallet to the head of the cap screw to force the bushing and pin from the upper shoe frame. Continue until the pin can be removed from the frame. 40015719 7 9. Press the bushing (1) from the pin (2) . 10. Inspection. Inspect the journal (2) for wear or damage. The diameter of the journal is to be 28.064 - 28.085 mm ( 1.105 - 1.106 in ) . Journals with diameters less than specified should be replaced. 40015726 8 40015727 9 9717 1 27/05/2004 K.62.B / 25