Case IH AFX8010 — CLEANING Primary cleaning

CROP PROCESSING - CLEANING Primary cleaning A. If no voltage is found, continue with step 8 . B. If high (> 5.2 volts ) is found, continue with step 7 . 7. Disconnect connector X023 , and use a multimeter to test for voltage on the front frame (FF) harness end of connector X023 pin 15. There should not be any voltage present. A. If high (> 5.2 volts ) is found, there is a short to high voltage in the front frame (FF) harness between connector X023 pin 15 and connector X020 pin J3-32 wire 721 yellow. Locate the short and repair. B. If no voltage is found, there is a short to high voltage in the lower frame (LF) harness between connector X088 pin C and connector X023 pin 15 wire 721 yellow.

Locate the short and repair. 8. Disconnect connector X088 , and use a multimeter to test for voltage on connector X088 pin A. There should be 5 volts present. A. If 5 volts is found, continue with step 11 . B. If high (> 5.2 volts ) is found, continue with step 9 . NOTE: This supply circuit is also used to supply power to the header tilt angle sensor, so a short to 12 volts anywhere on the supply circuit will also activate error code E0029-03 - Header Tilt Angle Sensor . 9. Disconnect connector X023 , and use a multimeter to test for voltage on connector X023 pin 17. There should be 5 volts present. A.

If 5 volts is found, there is a short to high voltage in the lower frame (LF) harness between connector X088 pin A and connector X023 pin 17 wire 727 pink. Locate the short and repair. B. If high (> 5.2 volts ) is found, continue with step 10 . 10. Disconnect connector X007 , and use a multimeter to test for voltage on the front frame (FF) harness end of connector X007 pin 22. There should be 5 volts present. A. If 5 volts is found, there is a short to high voltage in the feeder (FE) harness to between connector X081 pin A on the lateral float sensor R-02 and connector X007 pin 22 wire 757 pink. Locate the short and repair. B.

If high (> 5.2 volts ) is found, there is a short to high voltage in the front frame (FF) harness between connector X023 pin 17, connector X007 pin 22 and connector X020 pin J3-26 on one of the following wires; wire 757 pink, connector X007 pin 22 to FF harness splice, wire 727 pink, connector X023 pin 17 to FF harness splice, or wire 726 pink, FF harness splice to connector X020 pin J3-26. Locate the short and repair. 11. Operate the machine while monitoring the Universal Display Plus "DIAG" screen, "SIEVE ANG SEN" voltage. A. If no high out of range readings are indicated, erase the fault code and continue operation. B.

If the fault code immediately resets, determine which 12 volts circuit (such as the shoe leveling actuator) was activated to cause the short. 9717 1 27/05/2004 K.62.B / 75