CROP PROCESSING - CLEANING Primary cleaning and E0335-11 - Upper Sieve are displayed, continue with step 8 . D. If the lower sieve does not operate in either direction, and the fault code E0334-11 - Lower Sieve is displayed, continue with step 14 . E. If the lower sieve does not operate in either direction, and both fault codes E0300-06 - Lower Sieve Current Sense and E0334-11 - Lower Sieve are displayed, continue with step 30 . F. If the upper sieve operates in one direction only, and the fault code E0301-06 - Upper Sieve Current Sense is displayed, continue with step 31 . G.
If the upper sieve operates in one direction only, and both fault codes E0301-06 - Upper Sieve Current Sense and E0335-11 - Upper Sieve are displayed, continue with step 32 . H. If the upper sieve does not operate in either direction, and the fault code E0335-11 - Upper Sieve is displayed, continue with step 37 . I. If the upper sieve does not operate in either direction, and both fault codes E0301-06 - Upper Sieve Current Sense and E0335-11 - Upper Sieve are displayed, continue with step 45 . J. If both the lower sieve and upper sieve do not operate in either direction, and the fault codes E0334-11 - Lower Sieve and E0335-11 - Upper Sieve are displayed, continue with step 46 . K.
If both the lower sieve and upper sieve do not operate in either direction, and there are no fault codes displayed, continue with step 52 . 2. The lower sieve mechanism is mechanically bound up, resulting in high current draw. A. Disconnect the motor from the sieve, and manually open the louvers to fully clean the sieve. Inspect the control linkage for wear or binding. See the appropriate repair manual chapter for repair and adjustment of the lower sieve and control linkage. 3. Fault codes indicate circuit fault due to short to ground between the lower sieve motor and the Upper/lower sieve relay K18. Disconnect the batteries by removing the negative battery cables.
Unplug the lower sieve motor connector X228 . Use a multimeter to check for continuity between connector X228 pin D and chassis ground. A. If continuity is found, continue with Step 4 . B. If no continuity is found, erase the fault codes and continue operation. NOTE: The CCM module connects both sides of the circuit to ground when in neutral to "lock" the motor in position. Power must be removed from the module prior to testing for short to ground condition on the motor circuit to remove this ground path. 4. Disconnect connector X072 . Use a multimeter to check for continuity between connector X072 pin N and chassis ground. 9717 1 27/05/2004 K.62.B / 98