CROP PROCESSING - CLEANING Primary cleaning A. If no continuity is found, the short to ground is in the lower frame rear (LR) harness between connector X228 pin D and connector X072 pin N wire 790 white. Locate the short and repair. B. If continuity is found, continue with Step 5 . 5. Disconnect connector X025 . Use a multimeter to check for continuity between connector X025 pin 15 and chassis ground. A. If no continuity is found, the short to ground is in the straw hood front (SW) harness between connector X072 pin N and connector X025 pin 15 wire 790 white. Locate the short and repair. B. If continuity is found, continue with Step 6 . 6. Disconnect connector X219 .
Use a multimeter to check for continuity between connector X219 pin 2 and chassis ground. A. If no continuity is found, the short to ground is in the expansion (EX) harness between connector X025 pin 15 and connector X219 pin 2 wire 790 white. Locate the short and repair. B. If continuity is found, continue with Step 7 . 7. Disconnect connector X005 . Use a multimeter to check for continuity between connector X005 pin 16 and chassis ground. A. If no continuity is found, the short to ground is in the main frame (MF) harness between connector X219 pin 2 and connector X005 pin 16 wire 790 white. Locate the short and repair. B.
If continuity is found, the short to ground is in the cab main (CM) harness between connector X005 pin 16 and the Upper/lower sieve relay K18 pin 5 on the fuse panel. Locate the short and repair. 8. Fault codes indicate circuit fault due to short to ground between the lower sieve motor and/or the upper sieve motor and the CCM3 module. Disconnect the batteries by removing the negative battery cables. Unplug the lower sieve motor connector X228 and the upper sieve motor connector X227 . Use the multimeter to check for continuity between connector X228 pin E and chassis ground. A. If continuity is found, continue with Step 9 . B.
If no continuity is found, erase the fault codes and continue operation. NOTE: The CCM module connects both sides of the circuit to ground when in neutral to "lock" the motor in position. Power must be removed from the module prior to testing for short to ground condition on the motor circuit to remove this ground path. 9. Disconnect connector X072 . Use a multimeter to check for continuity between connector X072 pin P and chassis ground. A. If no continuity is found, the short to ground is in the lower frame rear (LR) harness between connector X072 pin P and connector X228 pin E wire 789 gray. Locate the short and repair. B. If continuity is found, continue with Step 10 . 10.
Disconnect connector X025 . Use a multimeter to check for continuity between connector X025 pin 14 and chassis ground. A. If continuity is found, the short to ground is in the expansion (EX) harness between connector X025 pin 14 and connector X013 pin J2-1 wire 785 gray. Locate the short and repair. B. If no continuity is found, the short to ground is in the straw hood front (SW) harness between connector X025 pin 14 and connector X072 pin J & P on one of the following wires:
- wire 785 gray, connector X025 pin 14 to harness splice - wire 791 gray, harness splice to connector X072 pin J - wire 789 gray, harness splice to connector X072 pin P Visually inspect the harnesses for damage, bent or dislocated pins, corroded terminals or broken wires. Locate the short to ground and repair. 11. Remove the Upper/lower sieve relay K18 from the fuse panel. Use a multimeter to check for continuity between the relay terminal 3 and chassis ground. 9717 1 27/05/2004 K.62.B / 99