CROP PROCESSING - CLEANING Primary cleaning B. If continuity is found, recheck the motor for continuity at Step 14 . Erase the fault codes and continue operation. 20. Disconnect connector X072 . Use a multimeter to check for continuity between connector X072 pin N and chassis ground. A. If continuity is found, the open circuit is in the lower frame rear (LR) harness between connector X228 pin D and connector X072 pin N wire 790 white. Locate the open and repair. B. If no continuity is found, continue with Step 21 . 21. Disconnect connector X025 . Use a multimeter to check for continuity between connector X025 pin 15 and chassis ground. A.
If continuity is found, the open circuit is in the straw hood front (SW) harness between connector X025 pin 15 and connector X072 pin N wire 790 white. Locate the open and repair. B. If no continuity is found, continue with Step 26 . 22. Disconnect connector X219 . Use a multimeter to check for continuity between connector X219 pin 2 and chassis ground. A. If continuity is found, the open circuit is in the expansion (EX) harness between connector X219 pin 2 and connector X025 pin 15 wire 790 white. Locate the open and repair. B. If no continuity is found, continue with Step 27 . 23. Remove the jumper wire between terminals 3 & 5 for relay K18 on the fuse panel.
Use a multimeter to check for continuity between Upper/lower sieve relay K18 terminal 5 and chassis ground. A. If no continuity is found, the open circuit is in wire 790 white from the fuse panel through connector X005 pin 16 to connector X219 pin 2. Locate the open and repair. B. If no continuity is found, continue with Step 28 . NOTE: Continuity check is being done back through circuit through the motor. The resistance will read significantly higher than previous tests, but should not be higher than 10 ohms above the motor resistance measured in Step 14. 24. Disconnect connector X005 . Use a multimeter to check for continuity between connector X005 pin 15 and chassis ground. A.
If continuity is found, the open circuit is in the cab main (CM) harness between the Upper/lower sieve relay K18 terminal 3 on the fuse panel connector X005 pin 15 wire 786 red. Locate the open and repair. 25. Disconnect connector X219 . Use a multimeter to check for continuity between connector X219 pin 1 and chassis ground. B. If no continuity is found, continue with Step 29 . A. If continuity is found, the open circuit is in the main frame (MF) harness between connector X005 pin 15 and connector X219 pin 1 wire 786 red. Locate the open and repair. B.
If no continuity is found, , the open circuit is in the expansion (EX) harness between connector X219 pin 1 and connector X013 pin J2-21 wire 786 red. Locate the open and repair. 26. Fault codes and operating condition indicate that the motor has shorted to ground. Disconnect lower sieve motor connector X228 . Measure between terminals D or E on the motor connector and a known good ground. There should be no continuity to ground. A. There is continuity to ground, indicating a short to ground in the motor. Replace the lower sieve motor. B. There is no continuity to ground. Erase the fault codes and continue operation. 27.
The upper sieve mechanism is mechanically bound up, resulting in high current draw. A. Disconnect the motor from the sieve, and manually open the louvers to fully clean the sieve. Inspect the control linkage for wear or binding. See the appropriate repair manual chapter for repair and adjustment of the upper sieve linkage. 9717 1 27/05/2004 K.62.B / 101