CROP PROCESSING - CLEANING Primary cleaning 44. Disconnect connector X219 . Use a multimeter to check for continuity between connector X219 pin 1 and chassis ground. A. If continuity is found, the open circuit is in the main frame (MF) harness between connector X219 pin 1 and connector X005 pin 15 wire 786 red. Locate the open and repair. B. If no continuity is found, , the open circuit is in the expansion (EX) harness between connector X219 pin 1 and connector X013 pin J2-21 wire 786 red. Locate the open and repair. 45. Fault codes and operating condition indicate that the motor has shorted to ground. Disconnect upper sieve motor connector X227 .
Measure between terminals D or E on the motor connector and a known good ground. There should be no continuity to ground. A. There is continuity to ground, indicating a short to ground in the motor. Replace the upper sieve motor. B. There is no continuity to ground. Erase the fault codes and continue operation. 46. Fault codes and operating condition indicates that there is an open circuit on shared wiring between the upper sieve motor and lower sieve motor circuits. Replace the Upper/lower sieve relay K18 on the fuse panel with a known good relay, and retest the upper and lower sieve circuit function. A.
If both circuits now function properly, the relay was faulty, and was not providing continuity between the work terminal 3 and terminals 4 & 5. Replace the relay. B. If both circuits still do not work, continue with Step 47 . 47. Ensure that the batteries are connected, and that fuse F23 is good. Remove the Upper/lower sieve relay K18 on the fuse panel. Use a multimeter to check for continuity between Upper/lower sieve relay K18 terminal 3 and chassis ground. A. If no continuity is found, continue with Step 48 . B. If continuity is found, continue with Step 50 . NOTE:
The CCM module connects both sides of the circuit to ground when in neutral to "lock" the motor in position, irregardless of key switch position, as long as it receives power through fuse F23. This ground path may be used to test for an open circuit condition. 48. Disconnect connector X005 . Use a multimeter to check for continuity between connector X005 pin 15 and chassis ground. A. If continuity is found, the open circuit is in the cab main (CM) harness between the Upper/lower sieve relay K18 terminal 3 on the fuse panel connector X005 pin 15 wire 786 red. Locate the open and repair. B. If no continuity is found, continue with Step 49 . 49. Disconnect connector X219 .
Use a multimeter to check for continuity between connector X219 pin 1 and chassis ground. A. If continuity is found, the open circuit is in the main frame (MF) harness between connector 219 pin 1 and connector X005 pin 15 wire 786 red. Locate the open and repair. B. If no continuity is found, , the open circuit is in the expansion (EX) harness between connector X219 pin 1 and connector X016 pin J2-21 wire 786 red. Locate the open and repair. 50. Disconnect connector X072 . Use a multimeter to check for continuity between connector X072 pin J or P and chassis ground. A. If continuity is found, erase the fault code and continue operation. 51. Disconnect connector X025 .
Use a multimeter to check for continuity between connector X025 pin 14 and chassis ground. B. If no continuity is found, continue with Step 51 . A. If continuity is found, the open circuit is in the straw hood front (SW) harness between connector X025 pin 14 and the harness splice on wire 785 gray. Locate the open and repair. 9717 1 27/05/2004 K.62.B / 137