CROP PROCESSING - CLEANING Primary cleaning B. If no continuity is found, the open circuit is in the expansion (EX) harness between connector X025 pin 14 and connector X013 pin J2-1 on wire 791 gray. Locate the open and repair. 52. If the upper sieve motor and lower sieve motor do not operate in either direction, and there are no error codes indicated, the supply power for the circuit may not be present. Remove fuse F27 and inspect. A. Fuse has failed. Go to Step 53 . B. Fuse is okay. Go to Step 56 . 53. If fuse has failed, replace the fuse. A. If fuse immediately fails, a short to ground exists on the wires to the CCM3 module connectors. Continue with Step 54 . B. Fuse is okay.
Go to Step 56 . 54. Disconnect connector X005 . Use a multimeter to check for continuity between the harness end of connector X005 pin 4 and chassis ground. A. If no continuity is found, there is a short to ground in the cab main (CM) harness between fuse F27 on the fuse panel and connector X005 pin 4 wire 031 red. Locate the short and repair. B. If continuity is found, continue with Step 55 . 55. Disconnect connector X034 . Use a multimeter to check for continuity between the harness end of connector X034 pin 2 and chassis ground. A. If no continuity is found, there is a short to ground in the main frame (MF) harness between connector X034 pin 2 and connector X005 pin 4 wire 031 red.
Locate the short and repair. B. If continuity is found, there is a short to ground in the expansion (EX) harness between connector X034 pin 2, connector X013 pin J2-11 and connector X014 pin J3-7 on one of the following wires: - wire 031 red, connector X034 pin 2 to harness splice - wire 511 red, harness splice to connector X013 pin J2-11 - wire 512 red, harness splice to connector X014 pin J3-7 Visually inspect the harnesses for damage, bent or dislocated pins, corroded terminals or broken wires. Locate the short to ground and repair. 56. Test for 12V power at connector X013 pin J2-11 on the CCM3 module under the cab. A.
If there is no power, there is an open circuit on the power wires to the CCM3 module. Continue with Step 57 . B. If there is power, go to Step 59 . 57. Disconnect connector X005 . Use a multimeter to check for 12V at connector X005 pin 4. A. If there is no power, there is an open circuit in the cab main (CM) harness between fuse F27 on the fuse panel and connector X005 pin 4 wire 031 red. Locate the open and repair. B. If power is found, continue with Step 58 . 58. Disconnect connector X034 . Use a multimeter to check for 12V at connector X034 pin 2. A.
If no continuity is found, there is an open circuit in the main frame (MF) harness between connector X034 pin 2 and connector X005 pin 4 wire 031 red. Locate the open and repair. B. If continuity is found, there is an open circuit in the expansion (EX) harness between connector X034 pin 2 and connector X013 pin J2-11 wire 031 red or 511 red. Locate the open and repair. 59. Test for continuity to ground at connector X013 pin J2-3 on the CCM3 module under the cab. A. If there is no continuity to ground, there is an open circuit in the expansion (EX) harness from connector X013 pin J2-3 on CCM3 module to the front frame ground #2 wire 520 black. Locate the open and repair.
After repair, go to Step 60 . B. If there is continuity to ground, go to Step 60 . 9717 1 27/05/2004 K.62.B / 138