Case IH AFX8010 — CLEANING Tailings return system

CROP PROCESSING - CLEANING Tailings return system Sensing system Tailing volume sensor - Short circuit to B+ (K.62.C.95.81 - G.30.B.54) AFX8010 E0147-03 - Tailings Volume Sensor Cause: The tailings volume sensor (R-24) circuit is shorted to high voltage, or the sensor ground is open. Possible failure modes: 1. Sensor supply or signal wiring is shorted to high voltage (12V). 2. Sensor ground wiring is open. 3. Module internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "CLEANING" sort menu, and select "TAILINGS VOL SEN" to check the voltage range.

Remove the cover from the bottom of the returns cross auger tube, and carefully move the arm on the tailings volume sensor while monitoring the voltage; the voltage should stay within range, and should change smoothly with movement of the sensor arm. The proper voltage range is 0.3 - 5.2 volts . A. If the voltage reading is high (> 5.2 volts ) out of range, continue with Step 2 . B. If the voltage reading is within the proper limits, the circuit may not be shorted at this time. Continue the troubleshooting at Step 7 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed.

Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. 2. Key off. Disconnect connector X445 , and use a multimeter to test for continuity to ground on connector X445 pin 3. There should be low resistance ( 1 ohms ) to ground. A. If continuity to ground is found ( 1 ohms ), continue with Step 5 . 3. Key off. Carefully remove connector X016 from the bottom of CCM2. Use a multimeter to test for continuity between connector X445 pin 3 and connector X016 pin J2-14. B. If no continuity is found, continue with step 3 . A.

If continuity is found, continue with Step 4 . B. If no continuity is found, there is an open circuit in the main frame (MF) harness between connector X445 pin 3 and connector X016 pin J2-14 wire 1190 blue, 425 blue or 465 blue. Locate the open and repair. 4. Key off. Use a multimeter to test for continuity between connector X016 pin J2-14 on CCM2 and chassis ground. There should be low resistance ( 1 ohms ) to ground. A. If no continuity is found, or there is high resistance (> 1 ohms ) to ground, the CCM2 module is not supplying a ground path for the sensor due to an internal failure. Replace the CCM2 module. B. If continuity is found, the ground path for the sensor tests okay.

Reconnect all connectors and retest for continuity to ground at Step 2 . 5. Key ON. Disconnect connector X445 , and use a multimeter to test for voltage on connector X445 pin 2. There should not be any voltage present. A. If no voltage is found, continue with Step 6 . B. If high (> 5.2 volts ) voltage is found, continue with step 8 . 9718 1 27/05/2004 K.62.C / 13