CROP PROCESSING - CLEANING Tailings return system 6. Disconnect connector X008 , and use a multimeter to test for voltage on connector X008 pin 30. There should not be any voltage present. A. If no voltage is found, there is a short to high voltage in the main frame (MF) harness between connector X008 and connector X445 wire 1164 yellow. Locate the short and repair. B. If high (> 5.2 volts ) voltage is found, there is a short to high voltage in the front frame (FF) harness between connector X008 pin 30 and connector X017 pin J3-22 wire 1164 yellow. Locate the short and repair. 7. Key ON. Disconnect connector X445 , and use a multimeter to test for voltage on connector X445 pin 1.
There should be 5 volts present. A. If 5 volts is found, continue with Step 7 . B. If high (> 5.2 volts ) voltage is found, there is a short to high voltage in the main frame (MF) harness. The should be displayed in the ERROR history screen. Refer to fault code E0165-03 - CCM2 J2 5V Reference to locate the short and repair. NOTE: This supply circuit is also used to supply power to the grain bin level switches S-28 & S-29, oil pressure sensor B-52, air filter switch S-61, parking brake pressure sensor B-53 and low control pressure sensor B-35, so a short to 12 volts anywhere on the supply circuit will activate this error code. 8.
Operate the machine while monitoring the Universal Display Plus "DIAG" screen. A. If no high out of range readings are indicated, erase the fault code and continue operation. B. If the fault code immediately resets, determine which 12 volts circuit (such as the concave clearance motor) was activated to cause the short. 9718 1 27/05/2004 K.62.C / 14