Case IH AFX8010 — RESIDUE HANDLING Spreader

CROP PROCESSING - RESIDUE HANDLING Spreader Sensing system Position sensor - Open circuit (K.64.D.95.81 - G.30.B.50) AFX8010 E0002-05 - Spreader Position Sensor Cause: The spreader position sensor (B11) circuit has an open. Possible failure modes: 1. Sensor supply wiring has an open. 2. Controller internal failure (internal regulator failure). Solution: 1. Enter the Universal Display Plus "DIAG" screen. Select the "RESIDUE" sort menu, and select "WINDROW POS SEN" to check the voltage range. The proper voltage sensor blocked by ferrous metal - 5.6 - 7.3 volts The proper voltage sensor unblocked by ferrous metal - 0.5 - 5.6 volts The proper voltage sensor when disconnected - 7.3 - 9.0 volts .

A. If the voltage reading is high 7.3 - 9.0 volts , continue with Step 2 . B. If the voltage reading is within the proper limits, continue the troubleshooting at Step 10 . NOTE: Visually inspect the wiring harness and connectors. Verify that the connector was fully installed. Inspect the terminals and wires at the connector for pushed back or corroded terminals or damaged wires. 2. Disconnect the spreader position sensor connector X240 . Use a jumper wire to short the harness end of connector X240 pin 2 to ground. A. If the voltage drops to 0 - 0.5 volts indicating a ground, the open circuit is not in the supply side of the circuit. Continue with Step 6 . B.

If the monitor still displays 7.3 - 9.0 volts , continue with Step 3 . 3. Disconnect the straw hood rear (SH) harness from the straw hood front (SW) harness at connector X071 . Use a jumper wire to short connector X071 pin 9 to ground. A. If the voltage drops to 0 - 0.5 volts indicating a ground, the open circuit is in the straw hood rear (SH) harness between connector X071 and the connector X240 pin 2 wire 415 yellow. Locate the open and repair. B. If the monitor still displays 7.3 - 9.0 volts , continue with Step 4 . 4. Disconnect the straw hood front (SW) harness from the main frame (MF) harness at connector X024 . Use a jumper wire to short connector X024 pin 4 to ground. A.

If the voltage drops to 0 - 0.5 volts indicating a ground, the open circuit is in the straw hood front (SW) harness between connector X071 and the connector X024 wire 415 yellow. Locate the open and repair. B. If the monitor still displays 7.3 - 9.0 volts , continue with Step 5 . 5. Disconnect the main frame (MF) harness from the front frame (FF) harness at connector X008 . Use a jumper wire to short connector X008 pin 6 to ground. A. If the voltage drops to 0 - 0.5 volts indicating a ground, the open circuit is in the main frame (MF) harness between connector X008 and the connector X024 wire 415 yellow. Locate the open and repair. B.

If the monitor still displays 7.3 - 9.0 volts , the open circuit is in the front frame (FF) harness between connector X008 and connector X020 pin J3-37 wire 415 yellow. Locate the open and repair. 9721 1 27/05/2004 K.64.D / 14